Evidence map›Paper›PMID 29713959›Full record

ArticleMolecular imaging and biology2018

Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

Guillaume Rucher, Lucie Cameliere, Jihene Fendri, Ahmed Abbas, Kevin Dupont, Said Kamel, Nicolas Delcroix, Axel Dupont, Ludovic Berger, Alain Manrique

Abstract read
PubMed Publisher
In one paragraph

Article in Molecular imaging and biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Guillaume RucherNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France.
Lucie CameliereNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France.
Jihene FendriNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France.
Ahmed AbbasNormandie Univ, UNICAEN, EPHE, INSERM, U1077, Neuropsychologie et Imagerie de la Mémoire Humaine, 14000, Caen, France.
Kevin DupontNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France.
Said KamelInserm UMR-1088, Université de Picardie Jules Verne, Centre Universitaire de Recherche en Santé (CURS), 80025, Amiens, France.
Nicolas DelcroixCNRS, UMS-3048, GIP Cyceron, Campus Jules Horowitz, 14000, Caen, France.
Axel DupontEsprimed SAS, 1 Mail du professeur Georges Mathé, 94800, Villejuif, France.
Ludovic BergerNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France.
Alain ManriqueNormandie Univ, UNICAEN, EA 4650, Cyceron, 14000, Caen, France. manrique@cyceron.fr.ORCID http://orcid.org/0000-0002-1578-0922
Normandie Université · FRInserm · FRCentre National de la Recherche Scientifique · FRLaboratoire d'études sur les monothéismes · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to assess the impact of positron emission tomography/X-ray computed tomography (PET/CT) acquisition and reconstruction parameters on the assessment of mineralization process in a mouse model of atherosclerosis. PROCEDURES: All experiments were performed on a dedicated preclinical PET/CT system. CT was evaluated using five acquisition configurations using both a tungsten wire phantom for in-plane resolution assessment and a bar pattern phantom for cross-plane resolution. Furthermore, the radiation dose of these acquisition configurations was calculated. The PET system was assessed using longitudinal line sources to determine the optimal reconstruction parameters by measuring central resolution and its coefficient of variation. An in vivo PET study was performed using uremic ApoE

resultsFor CT, the use of 1 × 1 and 2 × 2 binning detector mode increased both in-plane and cross-plane resolution. However, resolution improvement (163 to 62 μm for in-plane resolution) was associated with an important radiation dose increase (1.67 to 32.78 Gy). With PET, 3D-ordered subset expectation maximization (3D-OSEM) algorithm increased the central resolution compared to filtered back projection (1.42 ± 0.35 mm vs. 1.91 ± 0.08, p < 0.001). The use of 3D-OSEM with eight iterations and a zoom factor 2 yielded optimal PET resolution for preclinical study (FWHM = 0.98 mm). These PET reconstruction parameters allowed the detection of Na[

conclusionsOptimizing reconstruction parameters significantly impacted on the assessment of mineralization process in a preclinical model of accelerated atherosclerosis using Na[

Indexed as

Calcification, PhysiologicPositron Emission Tomography Computed TomographyAnimalsAtherosclerosisDisease Models, AnimalDose-Response Relationship, RadiationMaleMice, Inbred C57BLPhantoms, ImagingPhenotypeAtherosclerosisBone metabolismNa[18F]FPreclinical PET/CTVascular mineralization

Identifiers

PMID29713959
OpenAlexW2802689128

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.