Evidence map›Paper›PMID 29713809›Full record

ArticleJournal of materials science. Materials in medicine2018

Environmental fate and effect of biodegradable electro-spun scaffolds (biomaterial)-a case study.

A Irizar, M J B Amorim, K P Fuller, D I Zeugolis, J J Scott-Fordsmand

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

A IrizarDepartment of Bioscience, Aarhus University, Vejlsoevej 25, DK-8600, Silkeborg, Denmark.
M J B AmorimDepartment of Biology and CESAM, University of Aveiro, 3810-193, Aveiro, Portugal.
K P FullerRegenerative, Modular and Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland.
D I ZeugolisRegenerative, Modular and Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland.
J J Scott-FordsmandDepartment of Bioscience, Aarhus University, Vejlsoevej 25, DK-8600, Silkeborg, Denmark. jsf@bios.au.dk.
Aarhus University · DKScience Foundation Ireland · IEUniversity of Aveiro · PT

Funding

CESAM (UID/AMB/50017 - POCI-01-0145-FEDER-007638) via FCT/MCTES through national funds (PIDDAC), and the co-funding by the FEDER, within the PT2020 Partnership Agreement and Compete 2020) POCI-01-0145-FEDER-007638EU FP7 GREEN NANOMESH 263289H2020 LEIT Nanotechnologies GA No. 760928H2020 Marie Skłodowska-Curie Actions 676338Science Foundation Ireland 15/CDA/3629Science Foundation Ireland (IE) 13/RC/2073
6 · The paper itself

Abstract

Poly-ε-caprolactone (PCL) based medical devices are increasingly produced and thus, their presence in the environment is likely to increase. The present study analysed the biodegradation of PCL electro-spun scaffolds (alone) and PCL electro-spun scaffolds coated with human recombinant (hR) collagen and Bovine Achilles tendon (BAT) collagen in sewage sludge and in soil. Additionally, an eco-toxicological test with the model organism Enchytraeus crypticus was performed to assess environmental hazard of the produced materials in soils. The electro-spun scaffolds were exposed to activated sludge and three different soils for various time periods (0-7-14-21-28-56-180 days); subsequently the degradation was determined by weight loss and microscopical analysis. Although no toxicity occurred in terms of Enchytraeus crypticus reproduction, our data indicate that biodegradation was dependent on the coating of the material and exposure condition. Further, only partial PCL decomposition was possible in sewage treatment plants. Collectively, these data indicate that electro-spun PCL scaffolds are transferred to amended soils.

Indexed as

Absorbable ImplantsAnimalsBiocompatible MaterialsBiodegradation, EnvironmentalCattleElectroplatingEnvironmentMaterials TestingPolyestersSewageSoilTissue EngineeringTissue ScaffoldsToxicity TestsBiocompatible MaterialspolycaprolactonePolyestersSewageSoil

Identifiers

PMID29713809
OpenAlexW2802952149

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.