Evidence map›Paper›PMID 29707462›Full record

ArticlePlastic and reconstructive surgery. Global open2018

Three-dimensional Printed Surgical Simulator for Kirschner Wire Placement in Hand Fractures.

Michal Brichacek, Julian Diaz-Abele, Sarah Shiga, Christian Petropolis

Open access · goldAbstract read
In one paragraph

Article in Plastic and reconstructive surgery. Global open, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Observational
  3. Review
  4. Innovating Flexor Tendon Repair Training with a Three-dimensional Printed Model.Plastic and reconstructive surgery. Global open · 2024
    Article
  5. Article
  6. Simulation in Hand Surgery: A Literature Review.World journal of surgery · 2022
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Michal BrichacekSection of Plastic Surgery, Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada; and Division of Plastic Surgery, Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada.
Julian Diaz-AbeleSection of Plastic Surgery, Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada; and Division of Plastic Surgery, Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada.
Sarah ShigaSection of Plastic Surgery, Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada; and Division of Plastic Surgery, Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada.
Christian PetropolisSection of Plastic Surgery, Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada; and Division of Plastic Surgery, Department of Surgery, University of Ottawa, Ottawa, Ontario, Canada.
University of Ottawa · CAUniversity of Manitoba · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Closed reduction and percutaneous pinning (CRPP) of hand fractures can be a deceptively challenging procedure that requires significant hands-on time to teach and learn. We created a realistic three-dimensional simulator that can be used for teaching junior residents the CRPP. Computer-aided design and computer-aided manufacturing (CAD/CAM) software was used to create a three-dimensional hand model incorporating several common hand fractures: Bennett's fracture, transverse fifth metacarpal neck, and transverse second proximal phalanx. Three-dimensional printing was used to create molds in which the bones and soft tissue were poured. A polyurethane foam was utilized for the bones with iron incorporated to render them radiopaque, whereas silicone of varying viscosities was used for the soft tissues. Five plastic surgery residents and 5 consultants evaluated the model. Individuals then completed an anonymous 12-question survey evaluating the model based on realism, educational utility, and overall usefulness. Survey responses obtained from both residents and consultants were strongly in favor of the simulator. Average realism was graded as 4.48/5 by residents and 4.68/5 by consultants. Average educational utility was graded as 5/5 by residents and 4.95/5 by consultants. Average overall usefulness was graded as 5/5 by both groups. We created an anatomically accurate and realistic simulator for CRPP of hand fractures that was low cost and easily reproducible. Initial feedback was encouraging in regard to realism, educational utility, and overall usefulness.

Identifiers

PMID29707462
PMCPMC5908489
OpenAlexW2790002425

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390