Evidence map›Paper›PMID 29704127›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2018

Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.

Baptiste Boukebous, Pascal Guillon, Eric Vandenbussche, Marc Antoine Rousseau

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022
    Pooled it
  2. Article
  3. Biomechanical comparison of the undercut thread designFrontiers in bioengineering and biotechnology · 2022
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Baptiste BoukebousHopital Beaujon, Paris, France. baptisteboukebous@gmail.com.
Pascal GuillonHôpital du Raincy Montfermeil, Montfermeil, France.
Eric VandenbusscheHôpital Européen Georges Pompidou, Paris, France.
Marc Antoine RousseauHopital Beaujon, Paris, France.
Hôpital Beaujon · FRGroupe Hospitalier Intercommunal Le Raincy Montfermeil · FRHôpital Européen · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundScrew-plates disassembly incidence after pertrochanteric fracture (PF) amounts to 1 and 16% among the elderly population. The main occurrence is early cervical screw cut-out. The population at highest risk of disassembly remains difficult to identify. The correlation between femoral offset loss and disassembly occurrence has never been surveyed.

objectivesA radiological prognosis score for screw plate disassembly was defined to reflect trochanteric impaction (TI); it was based on a femoral offset ratio. STUDY DESIGN AND

methodsOur single-centre retrospective case-control study surveyed patients suffering from Dynamic Hip Screw (DHS, Synthes

resultsTwenty-three cases and 69 controls were surveyed. The case group's average age was 87; 70% of the cases were women. The main disassembly occurrence delay was after 27 days. Average TI was 26% within the patients global group and 12% within the control group (p < 10

conclusionsUsing the offset ratio tool, TI measurement was associated with a greater risk of DHS disassembly when it was higher than 21%. The exclusive use of a DHS device does not seem optimal for a TI > 21%. Weight-bearing may be prescribed for all the patients with a TI < 21%, provided good implant positioning is secured.

Indexed as

AgedAged, 80 and overBone PlatesBone ScrewsFemaleFracture Fixation, InternalHip FracturesHumansMaleOsteoporotic FracturesPrognosisProsthesis FailureRetrospective StudiesCut-outDHSDisassemblyDynamic hip screwsFemoral offsetPertrochanteric fracturesPlatesTADTip Apex distanceWeight-bearing

Identifiers

PMID29704127
OpenAlexW2800497621

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.