Evidence map›Paper›PMID 29702740›Full record

ArticleJournal of cardiovascular electrophysiology2018

Localization of ventricular activation origin using patient-specific geometry: Preliminary results.

Shijie Zhou, John L Sapp, Amir AbdelWahab, Petr Šťovíček, B Milan Horáček

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of cardiovascular electrophysiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Statistical guidance of VT ablation.Journal of cardiovascular electrophysiology · 2018
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Shijie ZhouSchool of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.
John L SappDepartment of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada.
Amir AbdelWahabDepartment of Medicine, Dalhousie University, Halifax, Nova Scotia, Canada.
Petr ŠťovíčekGeneral University Hospital, Charles University, Prague, Czech Republic.
B Milan HoráčekSchool of Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada.ORCID 0000-0001-6902-7787
Dalhousie University · CACharles University · CZ

Funding

CIHR
6 · The paper itself

Abstract

BACKGROUND AND

objectivesCatheter ablation of ventricular tachycardia (VT) may include induction of VT and localization of VT-exit site. Our aim was to assess localization performance of a novel statistical pace-mapping method and compare it with performance of an electrocardiographic inverse solution.

methodsSeven patients undergoing ablation of VT (4 with epicardial, 3 with endocardial exit) aided by electroanatomic mapping underwent intraprocedural 120-lead body-surface potential mapping (BSPM). Two approaches to localization of activation origin were tested: (1) A statistical method, based on multiple linear regression (MLR), which required only the conventional 12-lead ECG for a sufficient number of pacing sites with known origin together with patient-specific geometry of the endocardial/epicardial surface obtained by electroanatomic mapping; and (2) a classical deterministic inverse solution for recovering heart-surface potentials, which required BSPM and patient-specific geometry of the heart and torso obtained via computed tomography (CT).

resultsFor the MLR method, at least 10-15 pacing sites with known coordinates, together with their corresponding 12-lead ECGs, were required to derive reliable patient-specific regression equations, which then enabled accurate localization of ventricular activation with unknown origin. For 4 patients who underwent epicardial mapping, the median of localization error for the MLR was significantly lower than that for the inverse solution (10.6 vs. 27.3 mm, P  =  0.034); a similar result held for 3 patients who underwent endocardial mapping (7.7 vs. 17.1 mm, P  =  0.017). The pooled localization error for all epicardial and endocardial sites was also significantly smaller for the MLR compared with the inverse solution (P  =  0.005).

conclusionsThe novel pace-mapping approach to localizing the origin of ventricular activation offers an easily implementable supplement and/or alternative to the preprocedure inverse solution; its simplicity makes it suitable for real-time applications during clinical catheter-ablation procedures.

Indexed as

Models, CardiovascularBody Surface Potential MappingCatheter AblationHumansImaging, Three-DimensionalModels, AnatomicTachycardia, Ventricular12-lead ECGbody surface potential mappingcatheter ablationpace-mappingventricular tachycardia

Identifiers

PMID29702740
OpenAlexW2799632105

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.