Development of a cardiac loading device to monitor cardiac function during ex vivo graft perfusion.

Emilie Farine, Manuel U Egle, Alice C Boone, Sandro Christensen, Thierry P Carrel, Hendrik T Tevaearai Stahel, Sarah L Longnus

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 92% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Emilie FarineDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
Manuel U EgleDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
Alice C BooneDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
Sandro ChristensenDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
Thierry P CarrelDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
Hendrik T Tevaearai StahelDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.ORCID 0000-0001-9284-9842
Sarah L LongnusDepartment of Cardiovascular Surgery, Inselspital, Bern University Hospital, Bern, Switzerland.
University Hospital of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEx vivo heart perfusion systems, allowing continuous perfusion of the coronary vasculature, have recently been introduced to limit ischemic time of donor hearts prior to transplantation. Hearts are, however, perfused in an unloaded manner (via the aorta) and therefore, cardiac contractile function cannot be reliably evaluated.

objectivesWe aim to develop a ventricular loading device that enables monitoring of myocardial function in an ex vivo perfusion system. In this initial study, was to develop a prototype for rat experimentation.

methodsWe designed a device consisting of a ventricular balloon and a reservoir balloon, connected through an electronic check valve, which opens and closes in coordination with changes in ventricular pressure. All balloons were produced in our laboratory and their properties, particularly pressure-volume relationships, were characterized. We developed a mock ventricle in vitro test system to evaluate the device, which was ultimately tested in ex vivo perfused rat hearts.

resultsBalloon production was consistent and balloon properties were maintained over time and with use on the device. Results from in vitro and ex vivo experiments show that the device functions appropriately; hemodynamic function can be measured and compares well to measurements made in an isolated, working (loaded) rat heart preparation.

conclusionsOur cardiac loading device appears to reliably allow measurement of several left ventricular hemodynamic parameters and provides the opportunity to control ventricular load.

Indexed as

Heart TransplantationAnimalsEquipment DesignHemodynamicsIn Vitro TechniquesMaleModels, AnimalMonitoring, PhysiologicMyocardial ContractionPerfusionRatsRats, WistarVentricular Function, Left