ArticleJournal of medical Internet research2018
A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices.
Article in Journal of medical Internet research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03015363 (Comparison, Calibration, and Validation of the Non-invasive Cloud DX Pulsewave Health MonitorTM With Direct Invasive Radial and Central Arterial Measurements During Cardiac Catheterization), which is not on this map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison, Calibration, and Validation of the Non-invasive Cloud DX Pulsewave Health MonitorTM With Direct Invasive Radial and Central Arterial Measurements During Cardiac Catheterization
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Association of LIPC -250G/A and -514C/T polymorphisms and hypertension: a systematic review and meta-analysis.Lipids in health and disease · 2018Pooled it
- Choice of home blood pressure monitoring device: the role of device characteristics among Alaska Native and American Indian peoples.BMC cardiovascular disorders · 2022Trial
- Article
- Innovation and challenges of artificial intelligence technology in personalized healthcare.Scientific reports · 2024Review
- Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor.Biomedical engineering letters · 2023Article
- Transdermal iontophoresis delivery system for terazosin hydrochloride: anDrug delivery · 2021Article
- Applying a User-Centered Approach to Building a Mobile Personal Health Record App: Development and Usability Study.JMIR mHealth and uHealth · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundClinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility.
objectiveThe purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines.
methodsThe cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization.
resultsThe precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood pressure measurements.
conclusionsThe systolic pressure measurements of the wrist cuff have been iteratively calibrated using gold standard central (ascending aortic) pressure. This improves the accuracy of the indirect measures and potentially reduces the treatment gap. Devices that undergo auscultatory (indirect) calibration for licensing can be greatly improved by additional iterative calibration via intra-arterial (direct) measures of blood pressure. Further clinical trials with repeated use of the device over time are needed to assess the reliability of the device in accordance with current and evolving guidelines for informed decision making in the management of hypertension.
trial registrationClinicalTrials.gov NCT03015363; https://clinicaltrials.gov/ct2/show/NCT03015363 (Archived by WebCite at http://www.webcitation.org/6xPZgseYS).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials