Evidence map›Paper›PMID 29695092›Full record

ArticleSensors (Basel, Switzerland)2018

Towards an Electrochemical Immunosensor System with Temperature Control for Cytokine Detection.

Julia Metzner, Katrin Luckert, Karin Lemuth, Martin Hämmerle, Ralf Moos

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Julia MetznerRobert Bosch GmbH, Corporate Research, Robert-Bosch-Campus 1, D-71272 Renningen, Germany. julia.metzner2@gmail.com.
Katrin LuckertRobert Bosch GmbH, Corporate Research, Robert-Bosch-Campus 1, D-71272 Renningen, Germany.
Karin LemuthRobert Bosch GmbH, Corporate Research, Robert-Bosch-Campus 1, D-71272 Renningen, Germany.
Martin HämmerleDepartment of Functional Materials, University of Bayreuth, Universitätsstraße 30, D-95440 Bayreuth, Germany.
Ralf MoosDepartment of Functional Materials, University of Bayreuth, Universitätsstraße 30, D-95440 Bayreuth, Germany.
University of Bayreuth · DERobert Bosch (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The cytokine interleukin-13 (IL-13) plays a major role in airway inflammation and is a target of new anti-asthmatic drugs. Hence, IL-13 determination could be interesting in assessing therapy success. Thus, in this work an electrochemical immunosensor for IL-13 was developed and integrated into a fluidic system with temperature control for read-out. Therefore, two sets of results are presented. First, the sensor was set up in sandwich format on single-walled carbon nanotube electrodes and was read out by applying the hydrogen peroxide⁻hydroquinone⁻horseradish peroxidase (HRP) system. Second, a fluidic system was built up with an integrated heating function realized by Peltier elements that allowed a temperature-controlled read-out of the immunosensor in order to study the influence of temperature on the amperometric read-out. The sensor was characterized at the temperature optimum of HRP at 30 °C and at 12 °C as a reference for lower performance. These results were compared to a measurement without temperature control. At the optimum operation temperature of 30 °C, the highest sensitivity (slope) was obtained compared to lower temperatures and a limit of detection of 5.4 ng/mL of IL-13 was calculated. Taken together, this approach is a first step towards an automated electrochemical immunosensor platform and shows the potential of a temperature-controlled read-out.

Indexed as

Electrochemical TechniquesBiosensing TechniquesCytokinesElectrodesGoldHorseradish PeroxidaseImmunoassayTemperatureCytokinesGoldHorseradish Peroxidasecytokineselectrochemical immunosensorfluidic systemtemperature control

Identifiers

PMID29695092
PMCPMC5982244
OpenAlexW2801328375

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.