Evidence map›Paper›PMID 29694400›Full record

ArticlePloS one2018

A diffusion-matched principal component analysis (DM-PCA) based two-channel denoising procedure for high-resolution diffusion-weighted MRI.

Nan-Kuei Chen, Hing-Chiu Chang, Ali Bilgin, Adam Bernstein, Theodore P Trouard

Abstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Principal component analysis denoising improves sensitivity of MR diffusion to detect white matter injury in neuroHIV.Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2022
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Nan-Kuei ChenDepartment of Biomedical Engineering, University of Arizona, Tucson, Arizona, United States of America.ORCID 0000-0001-6564-4219
Hing-Chiu ChangDepartment of Diagnostic Radiology, The University of Hong Kong, Hong Kong, Hong Kong.
Ali BilginDepartment of Biomedical Engineering, University of Arizona, Tucson, Arizona, United States of America.
Adam BernsteinDepartment of Biomedical Engineering, University of Arizona, Tucson, Arizona, United States of America.
Theodore P TrouardDepartment of Biomedical Engineering, University of Arizona, Tucson, Arizona, United States of America.

Funding

Development of High-Speed and Quantitative Neuro MRI Technologies for Challenging Patient PopulationsR01NS102220 · NINDS · UNIVERSITY OF ARIZONA · PI CHEN, NAN-KUEI · 2018 to 2022
$2.1M
Imaging of Intrinsic Connectivity NetworksR01NS074045 · NINDS · DUKE UNIVERSITY · PI CHEN, NAN-KUEI · 2011 to 2015
$1.5M
Motion-immune neuro and body MRI for challenging patient populationsR21EB018419 · NIBIB · DUKE UNIVERSITY · PI CHEN, NAN-KUEI · 2014 to 2015
$435k
NIBIB NIH HHS R21 EB018419NIH HHS R01 NS 074045NIH HHS R21 EB 018419NINDS NIH HHS R01 NS074045NINDS NIH HHS R01 NS102220
6 · The paper itself

Abstract

Over the past several years, significant efforts have been made to improve the spatial resolution of diffusion-weighted imaging (DWI), aiming at better detecting subtle lesions and more reliably resolving white-matter fiber tracts. A major concern with high-resolution DWI is the limited signal-to-noise ratio (SNR), which may significantly offset the advantages of high spatial resolution. Although the SNR of DWI data can be improved by denoising in post-processing, existing denoising procedures may potentially reduce the anatomic resolvability of high-resolution imaging data. Additionally, non-Gaussian noise induced signal bias in low-SNR DWI data may not always be corrected with existing denoising approaches. Here we report an improved denoising procedure, termed diffusion-matched principal component analysis (DM-PCA), which comprises 1) identifying a group of (not necessarily neighboring) voxels that demonstrate very similar magnitude signal variation patterns along the diffusion dimension, 2) correcting low-frequency phase variations in complex-valued DWI data, 3) performing PCA along the diffusion dimension for real- and imaginary-components (in two separate channels) of phase-corrected DWI voxels with matched diffusion properties, 4) suppressing the noisy PCA components in real- and imaginary-components, separately, of phase-corrected DWI data, and 5) combining real- and imaginary-components of denoised DWI data. Our data show that the new two-channel (i.e., for real- and imaginary-components) DM-PCA denoising procedure performs reliably without noticeably compromising anatomic resolvability. Non-Gaussian noise induced signal bias could also be reduced with the new denoising method. The DM-PCA based denoising procedure should prove highly valuable for high-resolution DWI studies in research and clinical uses.

Indexed as

AgedAlgorithmsBrainCase-Control StudiesDiffusion Magnetic Resonance ImagingFemaleHumansImage Interpretation, Computer-AssistedMaleMiddle AgedParkinson DiseasePrincipal Component AnalysisSignal-To-Noise Ratio

Identifiers

PMID29694400
PMCPMC5918820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.