Perfusable Vascular Network with a Tissue Model in a Microfluidic Device.

Yuji Nashimoto, Yukako Teraoka, Ramin Banan Sadeghian, Akiko Nakamasu, Yuichiro Arima, Sanshiro Hanada, Hidetoshi Kotera, Koichi Nishiyama, Takashi Miura, Ryuji Yokokawa

Abstract readVideo-Audio Media
In one paragraph

Article in Journal of visualized experiments : JoVE, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Advances and challenges in human 3D solid tumor models.Advanced functional materials · 2025
    Article
  3. Review
  4. Article
  5. Mammary Microvessels are Sensitive to Menstrual Cycle Sex Hormones.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yuji NashimotoDepartment of Micro Engineering, Kyoto University.
Yukako TeraokaDepartment of Micro Engineering, Kyoto University.
Ramin Banan SadeghianDepartment of Micro Engineering, Kyoto University.
Akiko NakamasuGraduate School of Medical Sciences, Kyushu University.
Yuichiro ArimaInternational Research Center for Medical Sciences (IRCMS), Kumamoto University.
Sanshiro HanadaInternational Research Center for Medical Sciences (IRCMS), Kumamoto University.
Hidetoshi KoteraDepartment of Micro Engineering, Kyoto University.
Koichi NishiyamaInternational Research Center for Medical Sciences (IRCMS), Kumamoto University.
Takashi MiuraGraduate School of Medical Sciences, Kyushu University.
Ryuji YokokawaDepartment of Micro Engineering, Kyoto University; ryuji@me.kyoto-u.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A spheroid (a multicellular aggregate) is regarded as a good model of living tissues in the human body. Despite the significant advancement in the spheroid cultures, a perfusable vascular network in the spheroids remains a critical challenge for long-term culture required to maintain and develop their functions, such as protein expressions and morphogenesis. The protocol presents a novel method to integrate a perfusable vascular network within the spheroid in a microfluidic device. To induce a perfusable vascular network in the spheroid, angiogenic sprouts connected to microchannels were guided to the spheroid by utilizing angiogenic factors from human lung fibroblasts cultured in the spheroid. The angiogenic sprouts reached the spheroid, merged with the endothelial cells co-cultured in the spheroid, and formed a continuous vascular network. The vascular network could perfuse the interior of the spheroid without any leakage. The constructed vascular network may be further used as a route for supply of nutrients and removal of waste products, mimicking blood circulation in vivo. The method provides a new platform in spheroid culture toward better recapitulation of living tissues.

Indexed as

Lab-On-A-Chip DevicesHumansNeovascularization, PhysiologicTissue Culture TechniquesTissue Engineering

Identifiers

PMID29683439
PMCPMC5933371

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.