ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2018

Use of impedance-based catheter tip-to-tissue contact assessment (electroanatomic coupling index, ECI) in typical right atrial flutter ablation.

Massimiliano Maines, Francesco Peruzza, Alessandro Zorzi, Domenico Catanzariti, Carlo Angheben, Maurizio Del Greco

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Massimiliano MainesDepartment of Cardiology, Santa Maria del Carmine Hospital, Corso Verona 4, 38068, Rovereto, Trento, Italy. massimiliano.maines@apss.tn.it.
Francesco PeruzzaDepartment of Cardiology, Santa Maria del Carmine Hospital, Corso Verona 4, 38068, Rovereto, Trento, Italy.
Alessandro ZorziDepartment of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy.
Domenico CatanzaritiDepartment of Cardiology, Santa Maria del Carmine Hospital, Corso Verona 4, 38068, Rovereto, Trento, Italy.
Carlo AnghebenDepartment of Cardiology, Santa Maria del Carmine Hospital, Corso Verona 4, 38068, Rovereto, Trento, Italy.
Maurizio Del GrecoDepartment of Cardiology, Santa Maria del Carmine Hospital, Corso Verona 4, 38068, Rovereto, Trento, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe electrical coupling index (ECI) (Abbott, USA) is a marker of tissue contact and ablation depth developed particularly for atrial fibrillation treatment. We sought to evaluate if these measures can be also a marker of lesion efficacy during cavotricuspid isthmus (CTI) ablation for typical right atrial flutter.

methodsWe assessed the ECI values in patients undergoing typical right atrial flutter point-by-point ablation guided by the Ensite Velocity Contact™ (St. Jude Medical, now Abbott St. Paul, MN, USA) electroanatomic mapping system. ECI values were collected before, during (at the plateau), and after radiofrequency (RF) delivery. The physician was blinded to ECI and judged ablation efficacy according to standard parameters (impedance drop, local potential reduction, and/or split in two separate potentials). Patients were followed up at 3 and 12 months.

resultsFifteen consecutive patients (11 males, mean age 69.2 ± 10.6 years) with a history of typical right atrial flutter were included in this study. A total of 158 RF applications were assessed (mean 10.5 ± 6.6 per patient, range 6-28). The absolute and percentage ECI variations (pre-/post-ablation) were significantly greater when applications were effective (p < 0.001). A 12% drop in the ECI after ablation was identified by the ROC curve as the best cutoff value to discriminate between effective and ineffective ablation (sensitivity 94%, specificity 100%). Acute success was achieved in all patients with no complications and no recurrences during follow-up.

conclusionThe ECI appeared a reliable index to guide CTI ablation. A 12% drop of ECI during radiofrequency energy delivery was highly accurate in identifying effective lesion.

Indexed as

Cardiac CathetersElectric ImpedanceAgedAnatomic LandmarksAtrial FlutterBody Surface Potential MappingCohort StudiesEquipment DesignFemaleHumansMaleMiddle AgedPrognosisRecurrenceReoperationRisk AssessmentAtrial flutterCatheter ablation, electroanatomic mappingElectrophysiologySupraventricular arrhythmias