Evidence map›Paper›PMID 29679256›Full record

ArticleMedical & biological engineering & computing2018

Biomechanical features of six design of the delta external fixator for treating Pilon fracture: a finite element study.

Muhammad Hanif Ramlee, Mohd Ayub Sulong, Evelyn Garcia-Nieto, Daniel Angure Penaranda, Antonio Ros Felip, Mohammed Rafiq Abdul Kadir

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Muhammad Hanif RamleeMedical Devices and Technology Group (MEDITEG), Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), 81310, Johor Bahru, Johor, Malaysia. muhammad.hanif.ramlee@biomedical.utm.my.
Mohd Ayub SulongSport Innovation and Technology Centre (SITC), Institute of Human Centered Engineering (IHCE), Universiti Teknologi Malaysia, 81310, Johor Bahru, Johor, Malaysia.
Evelyn Garcia-NietoDepartment of Mechanical Engineering, ETSII, Technical University of Madrid, 28006, Madrid, Spain.
Daniel Angure PenarandaDepartment of Mechanical Engineering, ETSII, Technical University of Madrid, 28006, Madrid, Spain.
Antonio Ros FelipDepartment of Mechanical Engineering, ETSII, Technical University of Madrid, 28006, Madrid, Spain.
Mohammed Rafiq Abdul KadirMedical Devices and Technology Group (MEDITEG), Faculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia (UTM), 81310, Johor Bahru, Johor, Malaysia.
Universidad Politécnica de Madrid · ESUniversity of Technology Malaysia · MY

Funding

Potential Academic Scheme Q.J130000.2745.02K78Tier 1 Q.J130000.2545.20H20
6 · The paper itself

Abstract

Pilon fractures can be caused by high-energy vertical forces which may result in long-term patient immobilization. Many experts in orthopedic surgery recommend the use of a Delta external fixator for type III Pilon fracture treatment. This device can promote immediate healing of fractured bone, minimizing the rate of complications as well as allowing early mobilization. The characteristics of different types of the Delta frame have not been demonstrated yet. By using the finite element method, this study was conducted to determine the biomechanical characteristics of six different configurations (Model 1 until Model 6). CT images from the lower limb of a healthy human were used to reconstruct three-dimensional models of foot and ankle bones. All bones were assigned with isotropic material properties and the cartilages were assigned to exhibit hyperelasticity. A linear link was used to simulate 37 ligaments at the ankle joint. Axial loads of 70 and 350 N were applied at the proximal tibia to simulate the stance and swing phase. The metatarsals and calcaneus were fixed distally in order to prevent rigid body motion. A synthetic ankle bone was used to validate the finite element model. The simulated results showed that Delta3 produced the highest relative micromovement (0.09 mm, 7 μm) during the stance and swing phase, respectively. The highest equivalent von Mises stress was found at the calcaneus pin of the Delta4 (423.2 MPa) as compared to others. In conclusion, Delta1 external fixator was the most favorable option for type III Pilon fracture treatment. Graphical abstract ᅟ.

Indexed as

External FixatorsFinite Element AnalysisBiomechanical PhenomenaCalcaneusHumansLigamentsMovementReproducibility of ResultsStress, MechanicalTibiaTibial FracturesBiomechanicsDelta external fixatorFinite elementMicromovementPilon fracturesSynthetic bone

Identifiers

PMID29679256
OpenAlexW2800000974

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.