Evidence map›Paper›PMID 29677080›Full record

ArticleTransplantation2018

CORM-401 Reduces Ischemia Reperfusion Injury in an Ex Vivo Renal Porcine Model of the Donation After Circulatory Death.

Rabindra N Bhattacharjee, Mahms Richard-Mohamed, Qizhi Sun, Aaron Haig, Ghaleb Aboalsamh, Peter Barrett, Richard Mayer, Ibrahim Alhasan, Karen Pineda-Solis, Larry Jiang and 7 more

Open access · greenAbstract read
In one paragraph

Article in Transplantation, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 44 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Heme Oxygenase 1: A Defensive Mediator in Kidney Diseases.International journal of molecular sciences · 2021
    Review
  6. Frontiers in medicine · 2021
    Review
  7. Review
  8. The history of renal transplantation in Canada: A urologic perspective.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2020
    Article
  9. Article
  10. Review
  11. Article
  12. Machine preservation of donor kidneys in transplantation.Translational andrology and urology · 2019
    Review
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors at 3 institutions in 1 country.

Rabindra N BhattacharjeeMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Mahms Richard-MohamedMulti Organ Transplant Program, Western University, London, Canada.
Qizhi SunMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Aaron HaigMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Ghaleb AboalsamhMulti Organ Transplant Program, Western University, London, Canada.
Peter BarrettMulti Organ Transplant Program, Western University, London, Canada.
Richard MayerDepartment of Surgery, Western University, London, Canada.
Ibrahim AlhasanMulti Organ Transplant Program, Western University, London, Canada.
Karen Pineda-SolisMulti Organ Transplant Program, Western University, London, Canada.
Larry JiangMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Hajed AlharbiMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Manujendra SahaMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Eric PattersonCentre for Critical Illness Research, Lawson Health Research Institute, London, Ontario, Canada.
Alp SenerMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Gediminas CepinskasCentre for Critical Illness Research, Lawson Health Research Institute, London, Ontario, Canada.
Anthony M JevnikarMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Patrick P W LukeMatthew Mailing Centre for Translational Transplantation Studies, Western University, London, Canada.
Western University · CALawson Health Research Institute · CALondon Health Sciences Centre · CA

Funding

CIHR
6 · The paper itself

Abstract

backgroundCarbon monoxide (CO) inhalation protects organ by reducing inflammation and cell death during transplantation processes in animal model. However, using CO in clinical transplantation is difficult due to its delivery in a controlled manner. A manganese-containing CO releasing molecules (CORM)-401 has recently been synthesized which can efficiently deliver 3 molar equivalents of CO. We report the ability of this anti-inflammatory CORM-401 to reduce ischemia reperfusion injury associated with prolonged cold storage of renal allografts obtained from donation after circulatory death in a porcine model of transplantation.

methodsTo stimulate donation after circulatory death condition, kidneys from large male Landrace pig were retrieved after 1 hour warm ischemia in situ by cross-clamping the renal pedicle. Procured kidneys, after a brief flushing with histidine-tryptophan-ketoglutarate solution were subjected to pulsatile perfusion at 4°C with University of Wisconsin solution for 4 hours and both kidneys were treated with either 200 μM CORM-401 or inactive CORM-401, respectively. Kidneys were then reperfused with normothermic isogeneic porcine blood through oxygenated pulsatile perfusion for 10 hours. Urine was collected, vascular flow was assessed during reperfusion and histopathology was assessed after 10 hours of reperfusion.

resultsWe have found that CORM-401 administration reduced urinary protein excretion, attenuated kidney damage markers (kidney damage marker-1 and neutrophil gelatinase-associated lipocalin), and reduced ATN and dUTP nick end labeling staining in histopathologic sections. CORM-401 also prevented intrarenal hemorrhage and vascular clotting during reperfusion. Mechanistically, CORM-401 appeared to exert anti-inflammatory actions by suppressing Toll-like receptors 2, 4, and 6.

conclusionsCarbon monoxide releasing molecules-401 provides renal protection after cold storage of kidneys and provides a novel clinically relevant ex vivo organ preservation strategy.

Indexed as

AdenosineAllograftsAllopurinolAnimalsCarbon MonoxideCold IschemiaGlutathioneInsulinKidneyKidney TransplantationMaleManganeseModels, AnimalOrgan PreservationOrgan Preservation SolutionsRaffinoseAdenosineAllopurinolCarbon MonoxideGlutathioneInsulinManganeseOrgan Preservation SolutionsRaffinoseUniversity of Wisconsin-lactobionate solution

Identifiers

PMID29677080
PMCPMC7228623
OpenAlexW2800744908

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.