Evidence map›Paper›PMID 29675559›Full record

ArticleMikrochimica acta2018

Truncated aptamers for total and glycated hemoglobin, and their integration into a graphene oxide-based fluorometric method for high-throughput screening for diabetes.

Abrar Yousef Almusharraf, Shimaa Eissa, Mohammed Zourob

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 40 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Abrar Yousef AlmusharrafDepartment of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia.
Shimaa EissaDepartment of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia.
Mohammed ZourobDepartment of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh, 11533, Saudi Arabia. mzourob@alfaisal.edu.
Alfaisal University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The authors describe the identification of an effective binding region of aptamers against glycated (HbA1c) and total haemoglobin (tHb) by using a fluorometric assay. Truncation of the originally selected aptamers from 60 to 46 and 34 nucleotides for HbA1c and tHb, respectively, enhances the affinity for their targets. Moreover, shortening the aptamer sequences leads to a better conformational change after target binding which enabled the integration of the aptamers in a graphene oxide (GO)-based fluorometric assay. First, fluorescein-labelled truncated aptamers were physically absorbed onto the surface of GO surface via π-stacking interaction. This leads to quenching of fluorescence. Once the truncated aptamers bind the target protein, a conformational change is induced which results (a) )in the release of the aptamers from the surface of GO and (b) in the restoration of green fluorescence that is measured at 515 nm. The assay can be carried out in a microtiter plate format in homogeneous solution, this avoiding the steps of immobilization, incubation, and washing that are often necessary in immunoassays. This also reduces the time and the costs of the overall assay and allows for high throughput screening for diabetes. HbA1c can be detected in the range from 5.4 to 10.6%. The assay is selective for HbA1c over other proteins that commonly exist in blood. The results obtained by using this method compare well with those of a turbidimetric immunoassay that is typically applied in clinical laboratories. Graphical abstract Truncated aptamers for total and glycated hemoglobin were selected and integrated into a graphene oxide-based fluorescence detection assay for high-throughput screening for diabetes.

Indexed as

Aptamers, NucleotideBase SequenceBiosensing TechniquesDiabetes MellitusFluorescenceGlycated HemoglobinGraphiteHumansOxidesSpectrometry, FluorescenceAptamers, NucleotideGlycated HemoglobinGraphitehemoglobin A1c protein, humanOxidesClinical assayDiabetes diagnosisFluorescence assayHaemoglobin A1cMicroplate assayTruncation

Identifiers

PMID29675559
OpenAlexW2799934377

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.