Evidence map›Paper›PMID 29670830›Full record

ArticleTranslational vision science & technology2018

Improved High-Frequency Ultrasound Corneal Biometric Accuracy by Micrometer-Resolution Acoustic-Property Maps of the Cornea.

Daniel Rohrbach, Ronald H Silverman, Dan Chun, Harriet O Lloyd, Raksha Urs, Jonathan Mamou

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Advanced Topics in Quantitative Acoustic Microscopy.Advances in experimental medicine and biology · 2023
    Article
  4. Biomechanics of Ophthalmic Crosslinking.Translational vision science & technology · 2021
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Daniel RohrbachLizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA.
Ronald H SilvermanDepartment of Ophthalmology, Columbia University Medical Center, New York, NY, USA.
Dan ChunLizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA.
Harriet O LloydDepartment of Ophthalmology, Columbia University Medical Center, New York, NY, USA.
Raksha UrsDepartment of Ophthalmology, Columbia University Medical Center, New York, NY, USA.
Jonathan MamouLizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA.
Columbia University Irving Medical Center · USRiverside Research Institute · US

Funding

Instrumentation, Fabrication, and Design CoreP30EY019007 · NEI · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI Xin Zhang · 2010 to 2026
$12.9M
Ultrasound Scattering Models for Detection of Metastases in Axillary Lymph NodesR21EB016117 · NIBIB · RIVERSIDE RESEARCH INSTITUTE · PI MAMOU, JONATHAN · 2013 to 2014
$395k
NEI NIH HHS P30 EY019007NIBIB NIH HHS R21 EB016117
6 · The paper itself

Abstract

purposeMapping of epithelial thickness (ET) is useful for detection of keratoconus, a disease characterized by corneal thinning and bulging in which epithelial thinning occurs over the apex. In prior clinical studies, optical coherence tomography (OCT) measurements of ET were systematically thinner than those obtained by 40-MHz high-frequency ultrasound (HFU) where a constant speed of sound (

methodsTwelve unfixed pig corneas were snap-frozen and 6-μm sections were scanned using a custom-built SAM with an F-1.08, 500-MHz transducer and a 264-MHz bandwidth. Two-dimensional maps of

resultsSAM showed that the value of

conclusionSAM results demonstrated that the assumption of a constant value of TRANSLATIONAL RELEVANCE: The findings of this study have important implications for HFU-based ET measurements and will improve future keratoconus diagnosis by providing more-accurate ET estimates.

Indexed as

corneaepitheliumscanning acoustic microscopyspeed of soundstroma

Identifiers

PMID29670830
PMCPMC5901370
OpenAlexW2796698388

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.