Evidence map›Paper›PMID 29666670›Full record

ArticleJournal of healthcare engineering2018

Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera.

András Bánhalmi, János Borbás, Márta Fidrich, Vilmos Bilicki, Zoltán Gingl, László Rudas

Abstract read
In one paragraph

Article in Journal of healthcare engineering, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
  8. Article
  9. Observational
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Review
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

András BánhalmiInstitute of Informatics, University of Szeged, Szeged, 2 Árpád Square 6720, Hungary.ORCID 0000-0002-0285-710X
János Borbás2nd Department of Internal Medicine and Cardiology Clinic, University of Szeged, Szeged, 6 Semmelweis Street 6725, Hungary.
Márta FidrichInstitute of Informatics, University of Szeged, Szeged, 2 Árpád Square 6720, Hungary.
Vilmos BilickiInstitute of Informatics, University of Szeged, Szeged, 2 Árpád Square 6720, Hungary.
Zoltán GinglInstitute of Informatics, University of Szeged, Szeged, 2 Árpád Square 6720, Hungary.
László RudasDepartment of Anesthesiology and Intensive Therapy, University of Szeged, Szeged, 6 Semmelweis Street 6725, Hungary.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Heart rate variability (HRV) provides information about the activity of the autonomic nervous system. Because of the small amount of data collected, the importance of HRV has not yet been proven in clinical practice. To collect population-level data, smartphone applications leveraging photoplethysmography (PPG) and some medical knowledge could provide the means for it. Objective: To assess the capabilities of our smartphone application, we compared PPG (pulse rate variability (PRV)) with ECG (HRV). To have a baseline, we also compared the differences among ECG channels. Method: We took fifty parallel measurements using iPhone 6 at a 240 Hz sampling frequency and Cardiax PC-ECG devices. The correspondence between the PRV and HRV indices was investigated using correlation, linear regression, and Bland-Altman analysis. Results: High PPG accuracy: the deviation of PPG-ECG is comparable to that of ECG channels. Mean deviation between PPG-ECG and two ECG channels: RR: 0.01 ms-0.06 ms, SDNN: 0.78 ms-0.46 ms, RMSSD: 1.79 ms-1.21 ms, and pNN50: 2.43%-1.63%. Conclusions: Our iPhone application yielded good results on PPG-based PRV indices compared to ECG-based HRV indices and to differences among ECG channels. We plan to extend our results on the PPG-ECG correspondence with a deeper analysis of the different ECG channels.

Indexed as

SmartphoneAdultElectrocardiographyFemaleHeart RateHumansMalePhotoplethysmographyPulseSignal Processing, Computer-Assisted

Identifiers

PMID29666670
PMCPMC5832098

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.