ArticleBiochemia medica2018

Verification of a novel point-of-care HbA

Yufei Wang, Wei Peng, Junling Tang, Lu Dong, Chengchen Gu, Xin Zhang, Jian Zhou, Weiping Jia

Abstract readComparative Study
In one paragraph

Article in Biochemia medica, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yufei WangShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.
Wei PengWuxi Biohermes Bio&Medical Technology Co., Ltd., Wuxi, China.
Junling TangShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.
Lu DongShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.
Chengchen GuShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.
Xin ZhangShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.
Jian ZhouDepartment of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Clinical Center for Diabetes, Shanghai Key Clinical Center for Metabolic Disease, Shanghai, China.
Weiping JiaShanghai Diabetes Institute, Shanghai Jiao Tong University Affiliated Sixth People's Hospital; Shanghai Key Laboratory of Diabetes Mellitus, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA real world clinical study was designed and conducted to evaluate the performance of a novel point-of-care device for determination of glycated haemoglobin A MATERIALS AND

methodsFive hundred and fourteen subjects were included in this study, and divided into three groups. HbA

resultsResults obtained from A1C EZ 2.0 and all HPLC devices are correlated. Passing-Bablok regression analysis shows the equation of A1C EZ 2.0 results against the mean of HPLC devices with corresponding 95% confidence intervals (95% CI) for the intercept and slope is y = 0.10 (- 0.17 to 0.10) + 1.00 (1.00 to 1.04) x. Bland-Altman difference plot shows that the mean relative difference between A1C EZ 2.0 and Variant II Turbo, G8, Hb9210 and all HPLC results is 2.5%, 0.6%, 0.4% and 1.1%, respectively. In addition, 121 pairs of results determined by using both venous and capillary blood prove that the difference of two kinds of blood sample causes no notable variation when measured by A1C EZ 2.0. Precision study gives 2.3% and 1.9% of total coefficient of variation for normal and abnormal HbA

conclusionsHbA

Indexed as

AdolescentAdultAgedAged, 80 and overAnalysis of VarianceAutomation, LaboratoryCase-Control StudiesChromatography, High Pressure LiquidDiabetes MellitusFemaleGlycated HemoglobinHumansMaleMiddle AgedPoint-of-Care SystemsReproducibility of ResultsGlycated Hemoglobinhemoglobin A1c protein, humandiabetes mellitusevaluation studiesglycated haemoglobin A1cpoint-of-care testing

Identifiers

PMID29666558
PMCPMC5898960

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.