Evidence map›Paper›PMID 29666009›Full record

ArticleThe Journal of thoracic and cardiovascular surgery2018

In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.

Kerem Pekkan, Ibrahim Basar Aka, Ece Tutsak, Erhan Ermek, Haldun Balim, Ismail Lazoglu, Riza Turkoz

Open access · hybridAbstract readValidation StudyVideo-Audio Media
In one paragraph

Article in The Journal of thoracic and cardiovascular surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Kerem PekkanDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey. Electronic address: kpekkan@ku.edu.tr.
Ibrahim Basar AkaDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
Ece TutsakDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
Erhan ErmekDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
Haldun BalimDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
Ismail LazogluDepartment of Mechanical Engineering, Koç University, Sarıyer, Istanbul, Turkey.
Riza TurkozDepartment of Cardiovascular Surgery, School of Medicine, Acıbadem University, Istanbul, Turkey.
Koç University · TRAcıbadem University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPalliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation.

methodsBlade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios.

resultsThe prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow.

conclusionsOur experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure.

Indexed as

Fontan ProcedureHeart-Assist DevicesPalliative CareVenous PressureAortaFeasibility StudiesHeart Defects, CongenitalHumansProsthesis DesignVascular RemodelingVena Cava, InferiorVena Cava, SuperiorVentricular Functioncongenital heart diseaseFontanhemodynamicsmock-up circulation testspediatric ventricle assist devicesingle-ventricle physiologyvenous hemodynamics

Identifiers

PMID29666009
PMCPMC6021195
OpenAlexW2793466117

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked