ArticleThe Journal of thoracic and cardiovascular surgery2018
In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.
Article in The Journal of thoracic and cardiovascular surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 33 citations in OpenAlex.
- Autonomous Fontan pump: Computational feasibility study.JTCVS open · 2024Article
- Synchronous PIV measurements of a self-powered blood turbine and pump couple for right ventricle support.Scientific reports · 2024Article
- In vitro hemodynamic performance of a blood pump for self-powered venous assist in univentricular hearts.Scientific reports · 2024Article
- Switching the Left and the Right Hearts: A Novel Bi-ventricle Mechanical Support Strategy with Spared Native Single-Ventricle.Annals of biomedical engineering · 2023Article
- In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients.Cardiovascular engineering and technology · 2023Article
- Narrative review of single ventricle: where are we after 40 years?Translational pediatrics · 2023Review
- Optimizing percutaneous pulmonary valve implantation with patient-specific 3D-printed pulmonary artery models and hemodynamic assessment.Frontiers in cardiovascular medicine · 2023Article
- Complications and management of functional single ventricle patients with Fontan circulation: From surgeon's point of view.Frontiers in cardiovascular medicine · 2022Review
- Failures of the Fontan System in Univentricular Hearts and Mortality Risk in Heart Transplantation: A Systematic Review and Meta-Analysis.Life (Basel, Switzerland) · 2021Review
- Review on Mechanical Support and Cell-Based Therapies for the Prevention and Recovery of the Failed Fontan-Kreutzer Circulation.Frontiers in pediatrics · 2020Review
- Current spectrum, challenges and new developments in the surgical care of adults with congenital heart disease.Cardiovascular diagnosis and therapy · 2018Review
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPalliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation.
methodsBlade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios.
resultsThe prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow.
conclusionsOur experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.