ArticleNeurosurgical review2019
Safety and accuracy of spinal instrumentation surgery in a hybrid operating room with an intraoperative cone-beam computed tomography.
Article in Neurosurgical review, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 3 syntheses or guidelines pooled it, 23 citations in OpenAlex.
- The impact of augmented reality on radiation exposure during spine surgery: a systematic review.Neurosurgical review · 2026Pooled it
- The use of hybrid operating rooms in neurosurgery, advantages, disadvantages, and future perspectives: a systematic review.Acta neurochirurgica · 2023Pooled it
- A systematic review on the application of the hybrid operating room in surgery: experiences and challenges.Updates in surgery · 2022Pooled it
- Article
- Low Radiation Protocol for Intraoperative Robotic C-Arm Can Enhance Adolescent Idiopathic Scoliosis Deformity Correction Accuracy and Safety.Global spine journal · 2024Article
- Accurate Placement and Revisions for Cervical Pedicle Screws Placed With or Without Navigation: A Systematic Review and Meta-Analysis.Global spine journal · 2024Article
- Accuracy of Pedicle Screw Placement Comparing an Electronic Conductivity Device and a Multi-axis Angiography Unit with C-arm Fluoroscopy in Lumbar Fixation Surgery for Safety.Neurologia medico-chirurgica · 2021Article
- Comparative analysis of clinical factors associated with pedicle screw pull-out during or immediately after surgery between intraoperative cone-beam computed tomography and postoperative computed tomography.BMC musculoskeletal disorders · 2021Article
- The experience of surgery and endovascular procedure of cerebrovascular disease in the hybrid operating room; Multi-axis robotic C-arm DSA system.Journal of cerebrovascular and endovascular neurosurgery · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although spinal instrumentation technique has undergone revolutionary progress over the past few decades, it may still carry significant surgery-related risks. The purpose of the present study was to assess the radiological accuracy of spinal screw instrumentation using a hybrid operating room (OR) and quantify the related radiation exposure. This retrospective study included 33 cases of complex spine fusion surgeries that were conducted using a hybrid OR with a flat panel detector (FPD) angiography system. Twelve cases (36.4%) were cervical, and 21 (63.6%) were thoracolumbar. The average number of spine fusion levels was 3 and 4.8, respectively, at the cervical and thoracolumbar spine levels. A FPD angiography system was used for intraoperative cone-beam computed tomography (CBCT) to obtain multi-slice spine images. All operations were conducted under optimized radiation shielding. Entrance surface doses (ESDs) and exposure times were recorded in all cases. A total of 313 screws were placed. Satisfactory screw insertion could be achieved in all cases with safe screw placement in 97.4% and acceptable placement in 2.6%. None of the cases showed any significant anatomical violation by the screws. The radiation exposure to the patients was absolutely consistent with the desired ESD value, and that to the surgeons, under the annual dose limit. These results suggest that the hybrid OR with a FPD angiography system is helpful to achieve safe and precise spinal fusion surgery, especially in complex cases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.