Evidence map›Paper›PMID 29662767›Full record

ArticleJournal of orthopaedic translation2017

Reconstruction of the lateral tibia plateau fracture with a third triangular support screw: A biomechanical study.

Eduardo Moran, Ivan Zderic, Kajetan Klos, Paul Simons, Miguel Triana, R Geoff Richards, Boyko Gueorguiev, Mark Lenz

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic translation, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. [Research progress on biomechanics for internal fixation in tibial plateau fracture].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Review
  5. [Short-term effectiveness of lateral raft plate combined with Jail screw fixation in treatment of tibial plateau collapse fractures involved posterior-lateral column].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2023
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 3 countries.

Eduardo MoranAO Research Institute Davos, Davos, Switzerland.
Ivan ZdericAO Research Institute Davos, Davos, Switzerland.
Kajetan KlosDepartment for Foot and Ankle Surgery, Catholic Clinic of Mainz, Mainz, Germany.
Paul SimonsDepartment for Foot and Ankle Surgery, Catholic Clinic of Mainz, Mainz, Germany.
Miguel TrianaFundatión Cardioinfantil, Universidades el Bosque y Fundación Universitaria de Ciencias de la Salud, Bogota, Colombia.
R Geoff RichardsAO Research Institute Davos, Davos, Switzerland.
Boyko GueorguievAO Research Institute Davos, Davos, Switzerland.
Mark LenzDepartment of Trauma, Hand and reconstructive Surgery, University Hospital Jena, Jena, Germany.
AO Foundation · CHCatholic University of Applied Sciences · DEFundación Universitaria de Ciencias de la Salud · COJena University Hospital · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSplit fractures of the lateral tibia plateau in young patients with good bone quality are commonly treated using two minimally invasive percutaneous lag screws, followed by unloading of the knee joint. Improved stability could be achieved with the use of a third screw inserted either in the jail-technique fashion or with a triangular support screw configuration. The aim of this study was to investigate under cyclic loading the compliance and endurance of the triangular support fixation in comparison with the standard two lag-screw fixation and the jail technique.

methodsLateral split fractures of type AO/OTA 41-B1 were created on 21 synthetic tibiae and subsequently fixed with one of the following three techniques for seven specimens: standard fixation by inserting two partially threaded 6.5 mm cannulated lag screws parallel to each other and orthogonal to the fracture plane; triangular support fixation-standard fixation with one additional support screw at the distal end of the fracture at 30° proximal inclination; and jail fixation-standard fixation with one additional orthogonal support screw inserted in the medial nonfractured part of the bone. Mechanical testing was performed under progressively increasing cyclic compression loading. Fragment displacement was registered via triggered radiographic imaging.

resultsMean construct compliance was 3.847 × 10

conclusionTriangular support fixation enhanced interfragmentary stability at the ultimate stage of dynamic loading. However, the level of improvement seems to be limited and may not legitimate the intervention with an additional third screw.

Indexed as

jail fixationlag screwlateral split fracturemechanical testingtibia plateautriangular support fixation

Identifiers

PMID29662767
PMCPMC5866407
OpenAlexW2568218682

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.