Cardiac Magnetic Resonance Imaging Using an Open 1.0T MR Platform: A Comparative Study with a 1.5T Tunnel System.

Katharina Fischbach, Otrud Kosiek, Björn Friebe, Christian Wybranski, Bernhard Schnackenburg, Alexander Schmeisser, Jan Smid, Jens Ricke, Maciej Pech

Abstract read
In one paragraph

Article in Polish journal of radiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Katharina FischbachDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.
Otrud KosiekDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.
Björn FriebeDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.
Christian WybranskiDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.
Bernhard SchnackenburgMedical Physics, Philips Healthcare, Hamburg, Germany.
Alexander SchmeisserDepartment of Cardiology, University Clinic, Magdeburg, Germany.
Jan SmidDepartment of Cardiology, University Clinic, Magdeburg, Germany.
Jens RickeDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.
Maciej PechDepartment of Radiology and Nuclear Medicine, University Clinic Magdeburg, Magdeburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. MATERIAL/

methodFifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated.

resultsSNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41

conclusionsStandard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.

Indexed as

Black Blood SequencesB-SSFPCardiac MRICylindrical 1.5T MR SystemOpen 1.0T MR System

Identifiers

PMID29662579
PMCPMC5894020

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.