ArticlePloS one2018
ST waveform analysis for monitoring hypoxic distress in fetal sheep after prolonged umbilical cord occlusion.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 6 citations in OpenAlex.
- Acute severe hypoxia induces prolonged cardiac transcriptomic remodeling despite rapid functional recovery.Research square · 2026Article
- The diagnostic value of ultrasound detection of the fetal middle cerebral artery, umbilical artery blood flow and fetal movement reduction in fetal distress.American journal of translational research · 2021Article
- Why -aVF can be used in STAN as a proxy for scalp electrode-derived signal; reply to comments by Kjellmer et al.PloS one · 2019Article
- Article
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
11 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe inconclusive clinical results for ST-waveform analysis (STAN) in detecting fetal hypoxemia may be caused by the signal processing of the STAN-device itself. We assessed the performance of a clinical STAN device in signal processing and in detecting hypoxemia in a fetal sheep model exposed to prolonged umbilical cord occlusion (UCO).
methodsEight fetal lambs were exposed to 25 minutes of UCO. ECG recordings were analyzed during a baseline period and during UCO. STAN-event rates and timing of episodic T/QRS rise, baseline T/QRS rise and the occurrence of biphasic ST-waveforms, as well as signal loss, were assessed.
resultsDuring baseline conditions of normoxemia, a median of 40 (IQR, 25-70) STAN-events per minute were detected, compared to 10 (IQR, 2-22) during UCO. During UCO STAN-events were detected in five subjects within 10 minutes and in six subjects after 18 minutes, respectively. Two subjects did not generate any STAN-event during UCO. Biphasic ST event rate was reduced during UCO (median 0, IQR 0-5), compared to baseline (median 32, IQR, 6-55). ST-waveforms could not be assessed in 62% of the recording time during UCO, despite a good quality of the ECG signal.
conclusionsThe STAN device showed limitations in detecting hypoxemia in fetal sheep after prolonged UCO. The STAN device produced high false positive event rates during baseline and did not detect T/QRS changes adequately after prolonged fetal hypoxemia. During 14% of baseline and 62% of the UCO period, the STAN-device could not process the ECG signal, despite its good quality. Resolving these issues may improve the clinical performance of the STAN device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials