Evidence map›Paper›PMID 29659411›Full record

ArticleRetina (Philadelphia, Pa.)2019

ACCURACY AND PRECISION OF INTRAVITREAL INJECTIONS OF ANTI-VASCULAR ENDOTHELIAL GROWTH FACTOR AGENTS IN REAL LIFE: What Is Actually in the Syringe?

Itamar Loewenstein, Michaella Goldstein, Joseph Moisseiev, Elad Moisseiev

Abstract read
PubMed Publisher
In one paragraph

Article in Retina (Philadelphia, Pa.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Intravitreal injection delivered volume under different environmental and training conditions.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Intravitreal air bubbles following intravitreal injections: a comprehensive analysis.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2021
    Article
  8. Increasing vaccine supply with low dead-volume syringes and needles.International journal of pharmaceutics · 2021
    Article
  9. Review
  10. Issues with Intravitreal Administration of Anti-VEGF Drugs.Clinical ophthalmology (Auckland, N.Z.) · 2020
    Review
  11. Prefilled syringes for intravitreal drug delivery.Clinical ophthalmology (Auckland, N.Z.) · 2019
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Itamar LoewensteinDepartment of Ophthalmology, Tel Aviv Medical Center, Tel Aviv, Israel.
Michaella GoldsteinDepartment of Ophthalmology, Tel Aviv Medical Center, Tel Aviv, Israel.
Joseph MoisseievSackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Elad MoisseievDepartment of Ophthalmology, Tel Aviv Medical Center, Tel Aviv, Israel.
Tel Aviv University · ILSheba Medical Center · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy and precision of anti-vascular endothelial growth factor volume delivery by intravitreal injections in the clinical setup.

methodsVolume output was measured in 669 intravitreal injections administered to patients, calculated from the difference in syringe weight before and after expelling the drug. Three groups were included: prefilled bevacizumab 1.0 mL syringe (Group 1, n = 432), pre-filled ranibizumab in a small-volume syringe with low dead-space plunger design (Group 2, n = 125), and aflibercept drawn and injected using a 1.0-mL syringe (Group 3, n = 112). Accuracy was analyzed by mean absolute percentage error, and precision by coefficient of variation.

resultsVolume outputs in all 3 groups were significantly different from the target of 50 μL (P < 0.0001 for all), and mean absolute percentage error values were 12.25% ± 5.92% in Group 1, 13.60% ± 8.75% in Group 2, and 24.69% ± 14.84% in Group 3. No difference was found between groups 1 and 2, but both were significantly more accurate than Group 3 (P < 0.0001 for both).

conclusionThe current practices used for intravitreal injections are highly variable, with overdelivery of the anti-vascular endothelial growth factor drugs measured in most cases, but underdelivery in 16.3% of injections. Use of a prefilled syringe was associated with improved accuracy, and low dead-space plunger design may improve precision.

Indexed as

SyringesAngiogenesis InhibitorsFollow-Up StudiesHumansIntravitreal InjectionsReproducibility of ResultsRetinal DiseasesRetrospective StudiesVascular Endothelial Growth Factor AAngiogenesis InhibitorsVascular Endothelial Growth Factor A

Identifiers

PMID29659411
OpenAlexW2801691431

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked