ArticleMedical physics2018
VMAT optimization with dynamic collimator rotation.
Article in Medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 24 citations in OpenAlex.
- Automated decision support tool for static angle modulated ports configuration in VMAT with dynamic collimator rotation for head and neck cancer.Journal of applied clinical medical physics · 2026Article
- Dynamic modulated arc therapy (DMAT): A time-aware, modulation-steered optimization framework for next-generation radiotherapy delivery.Journal of applied clinical medical physics · 2026Article
- A simulation study of a novel spiral volumetric modulated arc therapy for enhanced dose delivery efficiency and quality in radiotherapy.Medical physics · 2026Article
- RapidArc Dynamic (RAD) multi-mechanical axis optimization achieves enhanced OAR sparing in cervical cancer: A dosimetric comparison study.Journal of applied clinical medical physics · 2026Article
- Impact of Isocenter Configuration and Flattening Filter Free Delivery on VMAT Planning for Synchronous Bilateral Breast Cancer.International journal of women's health · 2026Article
- A deep learning-based dose calculation method for volumetric modulated arc therapy.Radiation oncology (London, England) · 2024Article
- The effect of Inc parameter on VMAT radiotherapy plans quality for rectal cancer using Monaco TPS.Journal of applied clinical medical physics · 2024Article
- Optimization of collimator angle combined island blocking with parked gap achieves superior normal tissue sparing in SBRT planning of multiple liver lesions.Journal of applied clinical medical physics · 2024Article
- Optimization of collimator angles in dual-arc volumetric modulated arc therapy planning for whole-brain radiotherapy with hippocampus and inner ear sparing.Scientific reports · 2021Article
- Evaluation of novel AI-based extended field-of-view CT reconstructions.Medical physics · 2021Article
- DeepMC: a deep learning method for efficient Monte Carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy.Physics in medicine and biology · 2021Article
- ROAD: ROtational direct Aperture optimization with a Decoupled ring-collimator for FLASH radiotherapy.Physics in medicine and biology · 2021Article
- Many-isocenter optimization for robotic radiotherapy.Physics in medicine and biology · 2020Article
- Parallel beamlet dose calculation via beamlet contexts in a distributed multi-GPU framework.Medical physics · 2019Article
- Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
purposeAlthough collimator rotation is an optimization variable that can be exploited for dosimetric advantages, existing Volumetric Modulated Arc Therapy (VMAT) optimization uses a fixed collimator angle in each arc and only rotates the collimator between arcs. In this study, we develop a novel integrated optimization method for VMAT, accounting for dynamic collimator angles during the arc motion.
methodsDirect Aperture Optimization (DAO) for Dynamic Collimator in VMAT (DC-VMAT) was achieved by adding to the existing dose fidelity objective an anisotropic total variation term for regulating the fluence smoothness, a binary variable for forming simple apertures, and a group sparsity term for controlling collimator rotation. The optimal collimator angle for each beam angle was selected using the Dijkstra's algorithm, where the node costs depend on the estimated fluence map at the current iteration and the edge costs account for the mechanical constraints of multi-leaf collimator (MLC). An alternating optimization strategy was implemented to solve the DAO and collimator angle selection (CAS). Feasibility of DC-VMAT using one full-arc with dynamic collimator rotation was tested on a phantom with two small spherical targets, a brain, a lung and a prostate cancer patient. The plan was compared against a static collimator VMAT (SC-VMAT) plan using three full arcs with 60 degrees of collimator angle separation in patient studies.
resultsWith the same target coverage, DC-VMAT achieved 20.3% reduction of R50 in the phantom study, and reduced the average max and mean OAR dose by 4.49% and 2.53% of the prescription dose in patient studies, as compared with SC-VMAT. The collimator rotation co-ordinated with the gantry rotation in DC-VMAT plans for deliverability. There were 13 beam angles in the single-arc DC-VMAT plan in patient studies that requires slower gantry rotation to accommodate multiple collimator angles.
conclusionsThe novel DC-VMAT approach utilizes the dynamic collimator rotation during arc delivery. In doing so, DC-VMAT affords more sophisticated intensity modulation, alleviating the limitation previously imposed by the square beamlet from the MLC leaf thickness and achieves higher effective modulation resolution. Consequently, DC-VMAT with a single arc manages to achieve superior dosimetry than SC-VMAT with three full arcs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.