ReviewJournal of orthopaedics2018
Gait analysis methodology for the measurement of biomechanical parameters in total knee arthroplasties. A literature review.
Review in Journal of orthopaedics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.
- Effects of resistance training on gait velocity and knee adduction moment in knee osteoarthritis patients: a systematic review and meta-analysis.Scientific reports · 2021Pooled it
- Comparison of outcomes between gap balancing and measured resection techniques for total knee arthroplasty: A prospective, randomized, controlled trial.Acta orthopaedica et traumatologica turcica · 2021Trial
- The effect of extracorporeal shock wave therapy on the treatment of moderate to severe knee osteoarthritis and cartilage lesion.Medicine · 2019Trial
- Step-by-step insight into gait analysis: A narrative review unlocking knee biomechanics.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Review
- Gait analysis after TKA: Do different alignment strategies lead to different outcomes? A systematic review.Musculoskeletal surgery · 2026Review
- Accessible 2D video-based system for gait kinematic analysis: an inter-rater reliability study.Frontiers in bioengineering and biotechnology · 2026Article
- The combination of a medial pivot design with kinematic alignment principles in total knee arthroplasty can ensure a closer to normal knee kinematics than combining mechanical alignment and more traditional implant designs: An umbrella review.Journal of experimental orthopaedics · 2025Review
- Excessive Knee Internal Rotation during Grand Plié in Classical Ballet Female Dancers.Sports (Basel, Switzerland) · 2024Article
- Similar Biomechanical Behavior in Gait Analysis between Ceramic-on-Ceramic and Ceramic-on-XLPE Total Hip Arthroplasties.Life (Basel, Switzerland) · 2021Article
- Applications of Wearable Technology in a Real-Life Setting in People with Knee Osteoarthritis: A Systematic Scoping Review.Journal of clinical medicine · 2021Article
- Diagnosing gait disorders based on angular variations of knee and ankle joints utilizing a developed wearable motion sensor.Healthcare technology letters · 2021Article
- Correlation of quality of life with instrumented analysis of a total knee arthroplasty series at the long-term follow-up.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021Article
- Current clinical utilisation of wearable motion sensors for the assessment of outcome following knee arthroplasty: a scoping review.BMJ open · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Gait analysis using external skin markers provides scope for the study of kinematic and kinetic parameters shown on different total knee arthroplasties (TKA). Thus an appropriate methodology is of great importance for the collection and correlation of valid data. Calibration of equipment is of great importance before measurements, to assure accuracy. Force plates should be calibrated to 1080 Hz and optoelectronic cameras should use 120 Hz frequency, because of the nature of gait activity. Davis model which accurately defines the position of the markers is widely accepted and cited, for the gait analysis of TKA's. To ensure the reproducibility of the measurement, a static trial at the anatomical position must be captured. Following, all acquisitions of dynamic data must be checked for consistency in walking speed, and abnormal gait style because of fatigue or distraction. To establish the repeatability of the measurement, this procedure must be repeated at a pre-defined number of 3-5 gait cycles. Anthropometric measurements should be combined with three-dimensional marker data from the static trial to provide positions of the joint's center and define anatomical axes of total knee arthroplasty. Kinetic data should be normalized to bodyweight (BW) and percentage of BW and height depending on the study. External moments should also be calculated by using inverse dynamics and amplitude-normalized to body mass (Nm/kg). Gait analysis using external skin markers provides scope for the study of biomechanical parameters shown on different TKAs. Thus a standard gait analysis methodology when measuring TKA biomechanical parameters is necessary for the collection and correlation of accurate, adequate, valid and reproducible data. Further research should be done to clarify if the development of a specific kinematic model is appropriate for a more accurate definition of total knee implant joint center in measurements concerning 3D gait analysis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.