ArticleJournal of applied clinical medical physics2018
Improved dose homogeneity using electronic compensation technique for total body irradiation.
Article in Journal of applied clinical medical physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- The implementation of low instantaneous dose rate total body irradiation with linear accelerator in small-size treatment rooms.Journal of applied clinical medical physics · 2024Article
- A novel AP/PA total body irradiation technique using abutting IMRT fields at extended SSD.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In total body irradiation (TBI) utilizing large parallel-opposed fields, the manual placement of lead compensators has conventionally been used to compensate for the varying thickness throughout the body. The goal of this study is to pursue utilizing the modern electronic compensation (E-comp) technique to more accurately deliver dose to TBI patients. Bilateral parallel-opposed TBI treatment plans were created using E-comp for 15 patients for whom CT data had been previously acquired. A desirable fluence pattern was manually painted within each field to yield a uniform dose distribution. The conventional compensation technique was simulated within the treatment planning system (TPS) using a field-in-field (FIF) method. This allows for a meaningful evaluation of the E-comp technique in comparison to the conventional method. Dose-volume histograms (DVH) were computed for all treatment plans. The mean total body dose using E-comp deviates from the prescribed dose (4 Gy) by an average of 2.4%. The mean total body dose using the conventional compensation deviates from the prescribed dose by an average of 4.5%. In all cases, the mean body dose calculated using E-comp technique deviates less than 10% from that of conventional compensation. The average reduction in maximum dose using E-comp compared to that of the conventional method was 30.3% ± 6.6% (standard deviation). In all cases, the s-index for the E-comp technique was lower (10.5% ± 0.7%) than that of the conventional method (15.8% ± 4.4%), indicating a more homogenous dose distribution. In conclusion, a large reduction in maximum body dose can be seen using the proposed E-comp technique while still producing a mean body dose that accurately complies with the prescription dose. Dose homogeneity was quantified using s-index which demonstrated a reduction in hotspots with E-comp technique. Electronic compensation technique is capable of more accurately delivering a total body dose compared to conventional methods.