Evidence map›Paper›PMID 29654515›Full record

ArticleNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation2018

Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications.

H Lu, R J Bekker, M J Grundeken, P Woudstra, J J Wykrzykowska, J G P Tijssen, R J de Winter, K T Koch

Abstract read
In one paragraph

Article in Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. The 2010s in clinical drug-eluting stent and bioresorbable scaffold research: a Dutch perspective.Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2020
    Review
  6. Design of Self-Expanding Auxetic Stents Using Topology Optimization.Frontiers in bioengineering and biotechnology · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

H LuDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
R J BekkerDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
M J GrundekenDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
P WoudstraDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
J J WykrzykowskaDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
J G P TijssenDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
R J de WinterDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
K T KochDepartment of Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. k.t.koch@amc.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesWe sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent.

backgroundCoronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a substantial risk of stent malapposition. The self-apposing stent technique may reduce the risk of stent malapposition and therefore improve clinical outcomes.

methodsA total of 120 consecutive patients treated with the STENTYS stent were included (drug-eluting stent (DES) n = 101, bare-metal stent (BMS) n = 19). All lesions were scored for angiographic indications for the STENTYS stent, including aneurysms, ectasias, tapering, absolute diameters, bifurcation lesions, and saphenous vein grafts. Off-line quantitative coronary angiography analyses were performed pre-procedure and post-procedure. Five years follow-up was obtained including cardiac death, target vessel myocardial infarction (TV-MI), target vessel revascularisation, stent thrombosis, and the composite endpoint target vessel failure (cardiac death, TV-MI and target vessel revascularisation).

resultsAngiographic indications for STENTYS use were aneurysm (30%), ectasia (19%), tapering (27%), bifurcation lesions (8%), and saphenous vein graft lesions (16%) and absolute diameters (22%). Mean maximal diameter was 4.51 ± 0.99 mm. At 5‑year follow-up target vessel failure rates were 24.1% in the total cohort (DES 22.8% vs. BMS 33%, p = 0.26). Definite stent thrombosis rate was 3.8% at 5‑year follow-up in this cohort with complex and high-risk lesions (DES 4.5% vs. BMS 0%, p = 0.39).

conclusionsAngiographic indications for the use of the self-apposing stent were complex lesions with atypical coronary anatomy. Our data showed reasonable stent thrombosis rates at 5‑year follow-up, considering the high-risk lesion characteristics.

Indexed as

Complex lesionsCoronary artery diseaseStent designs

Identifiers

PMID29654515
PMCPMC5910317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.