ArticleCardiovascular engineering and technology2018
Realistic Vascular Replicator for TAVR Procedures.
Article in Cardiovascular engineering and technology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 24 citations in OpenAlex.
- Development of a Polymeric TAVR Device Tailored to Bicuspid Aortic Valve Patients Using In Silico Design Optimization and Evaluation.Annals of biomedical engineering · 2026Article
- A virtual patient authoring tool for transcatheter aortic valve replacement.International journal of computer assisted radiology and surgery · 2025Article
- AI-Powered Multimodal Modeling of Personalized Hemodynamics in Aortic Stenosis.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Soft robotic patient-specific hydrodynamic model of aortic stenosis and ventricular remodeling.Science robotics · 2023Article
- Mild Paravalvular Leak May Pose an Increased Thrombogenic Risk in Transcatheter Aortic Valve Replacement (TAVR) Patients-Insights from Patient Specific In Vitro and In Silico Studies.Bioengineering (Basel, Switzerland) · 2023Article
- Patient-specific in vitro testing for evaluating TAVR clinical performance-A complementary approach to current ISO standard testing.Artificial organs · 2021Article
- Mechanism of Vascular Injury in Transcatheter Aortic Valve Replacement.Sovremennye tekhnologii v meditsine · 2021Article
- An Inexpensive Cardiovascular Flow Simulator for Cardiac Catheterization Procedure Using a Pulmonary Artery Catheter.Frontiers in medical technology · 2021Article
- Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models.The international journal of cardiovascular imaging · 2020Article
- Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: adult cardiac conditions.3D printing in medicine · 2020Article
- New Insights into Valve Hemodynamics.Rambam Maimonides medical journal · 2020Review
- Development of a Stand-Alone Independent Graphical User Interface for Neurological Disease Prediction with Automated Extraction and Segmentation of Gray and White Matter in Brain MRI Images.Journal of healthcare engineering · 2019Article
- Novel Polymeric Valve for Transcatheter Aortic Valve Replacement Applications: In Vitro Hemodynamic Study.Annals of biomedical engineering · 2019Article
- Principles of TAVR valve design, modelling, and testing.Expert review of medical devices · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.