Evidence map›Paper›PMID 29654373›Full record

ArticleJournal of medical systems2018

An Adaptive Monitoring Scheme for Automatic Control of Anaesthesia in dynamic surgical environments based on Bispectral Index and Blood Pressure.

Yu-Ning Yu, Faiyaz Doctor, Shou-Zen Fan, Jiann-Shing Shieh

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Catheter-mounted smart hydrogel ultrasound resonators for intravenous analyte monitoring.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021
    Article
  3. Review
  4. Article
  5. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Yu-Ning YuDepartment of Mechanical Engineering, and Innovation Center for Big Data and Digital Convergence, Yuan Ze University, Chungli, 320, Taiwan, Republic of China.
Faiyaz DoctorSchool of Computer Science and Electronic Engineering, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK. fdocto@essex.ac.uk.ORCID http://orcid.org/0000-0002-8412-5489
Shou-Zen FanDepartment of Anesthesiology, National Taiwan University Hospital, Taipei, 100, Taiwan, Republic of China.
Jiann-Shing ShiehDepartment of Mechanical Engineering, and Innovation Center for Big Data and Digital Convergence, Yuan Ze University, Chungli, 320, Taiwan, Republic of China. jsshieh@saturn.yzu.edu.tw.
Yuan Ze University · TWNational Taiwan University Hospital · TWUniversity of Essex · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

During surgical procedures, bispectral index (BIS) is a well-known measure used to determine the patient's depth of anesthesia (DOA). However, BIS readings can be subject to interference from many factors during surgery, and other parameters such as blood pressure (BP) and heart rate (HR) can provide more stable indicators. However, anesthesiologist still consider BIS as a primary measure to determine if the patient is correctly anaesthetized while relaying on the other physiological parameters to monitor and ensure the patient's status is maintained. The automatic control of administering anesthesia using intelligent control systems has been the subject of recent research in order to alleviate the burden on the anesthetist to manually adjust drug dosage in response physiological changes for sustaining DOA. A system proposed for the automatic control of anesthesia based on type-2 Self Organizing Fuzzy Logic Controllers (T2-SOFLCs) has been shown to be effective in the control of DOA under simulated scenarios while contending with uncertainties due to signal noise and dynamic changes in pharmacodynamics (PD) and pharmacokinetic (PK) effects of the drug on the body. This study considers both BIS and BP as part of an adaptive automatic control scheme, which can adjust to the monitoring of either parameter in response to changes in the availability and reliability of BIS signals during surgery. The simulation of different control schemes using BIS data obtained during real surgical procedures to emulate noise and interference factors have been conducted. The use of either or both combined parameters for controlling the delivery Propofol to maintain safe target set points for DOA are evaluated. The results show that combing BIS and BP based on the proposed adaptive control scheme can ensure the target set points and the correct amount of drug in the body is maintained even with the intermittent loss of BIS signal that could otherwise disrupt an automated control system.

Indexed as

Blood PressureConsciousness MonitorsAdultAgedAged, 80 and overAnesthesiaFemaleFuzzy LogicHeart RateHumansImage Processing, Computer-AssistedMaleMiddle AgedModels, BiologicalModels, TheoreticalMonitoring, IntraoperativeAnesthesiaBispectral indexBlood pressureDepth of anesthesiaPharmacodynamics and pharmacokineticPropofolType-2 Self Organizing Fuzzy Logic Controllers

Identifiers

PMID29654373
OpenAlexW2797604986

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.