ArticleThe British journal of ophthalmology2018
Effect of phacoemulsification on facility of outflow.
Article in The British journal of ophthalmology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 29 citations in OpenAlex.
- Trial
- A multicenter prospective comparative study evaluating cataract surgery and endoscopic cyclophotocoagulation either with or without iStent inject implantation in Brazilian patients with glaucoma.International ophthalmology · 2023Trial
- Factors Influencing Intraocular Pressure Elevation During Hemodialysis.Translational vision science & technology · 2026Observational
- Comparative Study of Outflow Facility and Intraocular Pressure in Kahook Dual Blade and iStent Inject - A Consecutive Case Series.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Retrospective Single-Center Outcomes After a First Bimatoprost Sustained-Release Implant.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Article
- Prediction model for elevated intraocular pressure risk after silicone oil filling based on clinical features.Frontiers in medicine · 2023Article
- Phacoemulsification combined with micropulse cyclodiode laser in glaucoma patients: efficacy and safety.Eye (London, England) · 2022Article
- Recent advances in optical coherence tomography for anterior segment imaging in small animals and their clinical implications.The ocular surface · 2022Review
- Intraocular pressure changes after phacoemulsification in pseudoexfoliation versus healthy eyes.BMC ophthalmology · 2021Article
- Aqueous humour outflow imaging: seeing is believing.Eye (London, England) · 2021Review
- Predictive factors for the IOP reduction in phacocanaloplasty with suprachoroidal drainage.International ophthalmology · 2020Article
- Acute Effects of Intraocular Pressure-Induced Changes in Schlemm's Canal Morphology on Outflow Facility in Healthy Human Eyes.Investigative ophthalmology & visual science · 2020Article
- Effect of prior glaucoma surgery on intraocular pressure immediately after anti-vascular endothelial growth factor injection.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2019Article
- Incidence of Glaucoma or Ocular Hypertension After Repeated Anti-Vascular Endothelial Growth Factor Injections for Macular Degeneration.Clinical ophthalmology (Auckland, N.Z.) · 2019Article
- Outcomes of Complex Cataract Surgery in Patients with Primary Open-angle Glaucoma.Journal of current glaucoma practiceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePhacoemulsification has been shown to reduce intraocular pressure (IOP). The mechanism of action is thought to be via increased trabecular outflow facility. However, studies on the relationship between phacoemulsification and outflow facility have been inconsistent. This study intended to examine the change in electronic Schiotz tonographic outflow facility (TOF) and IOP measurements following phacoemulsification.
methodsPatients who were due to undergo a standard clear corneal incision phacoemulsification with intraocular lens (IOL) implantation, at St Thomas' Hospital, were invited to participate in this study. IOP was measured using Goldmann's applanation tonometer, and TOF was measured by electronic Schiotz tonography at baseline and at 3, 6 and 12 months postoperatively.
resultsForty-one patients were recruited. Tonography data for 27 patients were reliable and available at all time points. Eleven cases had primary open angle glaucoma and cataract, while 16 patients had cataract only. Mean IOP reduced at every time point postoperatively significantly compared with baseline. TOF improved significantly after cataract extraction at all time points (baseline of 0.14±0.06 vs 0.18±0.09 at 3 months, P=0.02 and 0.20±0.09 at 6 months, P=0.003, 0.17±0.07 µL/min mmHg at 12 months, P=0.04). Five contralateral eyes of patients with cataracts only who did not have any intraocular surgery during the follow-up period were used as comparison. Their IOP and TOF did not change significantly at any postoperative visits.
conclusionThis is the first study using electronic Schiotz tonography with documented anterior chamber depth and gonioscopy after modern cataract surgery (CS) with phacoemulsification and IOL implantation. We demonstrated that phacoemulsification increases TOF and this fully accounts for the IOP reduction following CS. ISTCRN REGISTRATION NUMBER: ISRCTN04247738.