Evidence map›Paper›PMID 29652834›Full record

ArticleSensors (Basel, Switzerland)2018

Easy-to-Build Textile Pressure Sensor.

Francisco Pizarro, Piero Villavicencio, Daniel Yunge, Mauricio Rodríguez, Gabriel Hermosilla, Ariel Leiva

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
3.7field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 64 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Advances in Printed Electronic Textiles.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Textile-Based Mechanical Sensors: A Review.Materials (Basel, Switzerland) · 2021
    Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Francisco PizarroPontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. francisco.pizarro.t@pucv.cl.
Piero VillavicencioPontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. piero.villavicencio.a@mail.pucv.cl.
Daniel YungePontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. daniel.yunge@pucv.cl.ORCID 0000-0001-7149-2768
Mauricio RodríguezPontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. mauricio.rodriguez.g@pucv.cl.ORCID 0000-0002-1235-8566
Gabriel HermosillaPontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. gabriel.hermosilla@pucv.cl.
Ariel LeivaPontificia Universidad Católica de Valparaíso, Escuela de Ingeniería Eléctrica, Avenida Brasil 2147, Valparaíso 2362804, Chile. ariel.leiva@pucv.cl.
Pontificia Universidad Católica de Valparaíso · CL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This article presents the design, construction, and evaluation of an easy-to-build textile pressure resistive sensor created from low-cost conventional anti-static sheets and conductive woven fabrics. The sensor can be built quickly using standard household tools, and its thinness makes it especially suitable for wearable applications. Five sensors constructed under such conditions were evaluated, presenting a stable and linear characteristic in the range 1 to 70 kPa. The linear response was modeled and fitted for each sensor individually for comparison purposes, confirming a low variability due to the simple manufacturing process. Besides, the recovery times of the sensors were measured for pressures in the linear range, observing, for example, an average time of 1 s between the moment in which a pressure of 8 kPa was no longer applied, and the resistance variation at the 90% of its nominal value. Finally, we evaluated the proposed sensor design on a classroom application consisting of a smart glove that measured the pressure applied by each finger. From the evaluated characteristics, we concluded that the proposed design is suitable for didactic, healthcare and lifestyle applications in which the sensing of pressure variations, e.g., for activity assessment, is more valuable than accurate pressure sensing.

Indexed as

easy-to-buildpressure measurementtextileswearable sensors

Identifiers

PMID29652834
PMCPMC5948620
OpenAlexW2797058371

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked