Evidence map›Paper›PMID 29651607›Full record

ArticlePediatric radiology2018

Detecting inflammation in inflammatory bowel disease - how does ultrasound compare to magnetic resonance enterography using standardised scoring systems?

Joy L Barber, Alexsandra Zambrano-Perez, Øystein E Olsen, Fevronia Kiparissi, Mila Baycheva, Daniela Knaflez, Neil Shah, Tom A Watson

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Guideline
  2. Review
  3. Review
  4. Review
  5. Article
  6. Magnetic resonance enterography and bowel ultrasonography in Saudi Arabian patients with Crohn's disease: A correlation study.Saudi journal of gastroenterology : official journal of the Saudi Gastroenterology Association
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Joy L BarberDepartment of Paediatric Radiology, Great Ormond Street Hospital NHS Foundation Trust, London, Wc1N 3JH, UK.
Alexsandra Zambrano-PerezDepartment of Paediatric Gastroenterology, Great Ormond Street Hospital NHS Foundation Trust, London, UK.
Øystein E OlsenDepartment of Paediatric Radiology, Great Ormond Street Hospital NHS Foundation Trust, London, Wc1N 3JH, UK.
Fevronia KiparissiDepartment of Paediatric Gastroenterology, Great Ormond Street Hospital NHS Foundation Trust, London, UK.
Mila BaychevaDepartment of Paediatric Gastroenterology, Great Ormond Street Hospital NHS Foundation Trust, London, UK.
Daniela KnaflezDepartment of Paediatric Gastroenterology, Great Ormond Street Hospital NHS Foundation Trust, London, UK.
Neil ShahDepartment of Paediatric Gastroenterology, Great Ormond Street Hospital NHS Foundation Trust, London, UK.
Tom A WatsonDepartment of Paediatric Radiology, Great Ormond Street Hospital NHS Foundation Trust, London, Wc1N 3JH, UK. Tom.watson@gosh.nhs.uk.
Great Ormond Street Hospital for Children NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMagnetic resonance enterography (MRE) is the current gold standard for imaging in inflammatory bowel disease, but ultrasound (US) is a potential alternative.

objectiveTo determine whether US is as good as MRE for the detecting inflamed bowel, using a combined consensus score as the reference standard. MATERIALS AND

methodsWe conducted a retrospective cohort study in children and adolescents <18 years with inflammatory bowel disease (IBD) at a tertiary and quaternary centre. We included children who underwent MRE and US within 4 weeks. We scored MRE using the London score and US using a score adapted from the METRIC (MR Enterography or Ultrasound in Crohn's Disease) trial. Four gastroenterologists assessed an independent clinical consensus score. A combined consensus score using the imaging and clinical scores was agreed upon and used as the reference standard to compare MRE with US.

resultsWe included 53 children. At a whole-patient level, MRE scores were 2% higher than US scores. We used Lin coefficient to assess inter-observer variability. The repeatability of MRE scores was poor (Lin 0.6). Agreement for US scoring was substantial (Lin 0.95). There was a significant positive correlation between MRE and clinical consensus scores (Spearman's rho = 0.598, P=0.0053) and US and clinical consensus scores (Spearman's rho = 0.657, P=0.0016).

conclusionUS detects as much clinically significant bowel disease as MRE. It is possible that MRE overestimates the presence of disease when using a scoring system. This study demonstrates the feasibility of using a clinical consensus reference standard in paediatric IBD imaging studies.

Indexed as

AdolescentChildFemaleHumansInflammatory Bowel DiseasesMagnetic Resonance ImagingMaleReproducibility of ResultsRetrospective StudiesSensitivity and SpecificityUltrasonographyAdolescentsChildrenDiagnostic accuracyInflammatory bowel diseaseMagnetic resonance imagingReproducibilityUltrasound

Identifiers

PMID29651607
OpenAlexW2797206963

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.