Evidence map›Paper›PMID 29644401›Full record

ArticleMedizinische Klinik, Intensivmedizin und Notfallmedizin2019

[Skill retention using extraglottic airways in out-of-hospital emergencies: efficacy and long-term results of simulator-based medical education : A prospective follow-up study].

V Mann, F Limberg, S T W Mann, S Little, M Müller, M Sander, R Röhrig

Abstract read
PubMed Publisher
In one paragraph

Article in Medizinische Klinik, Intensivmedizin und Notfallmedizin, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

V MannKlinik für Anästhesiologie, Operative Intensivmedizin und Schmerztherapie, Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen, Rudolf-Buchheim-Str. 7, 35385, Gießen, Deutschland. valesco.mann@chiru.med.uni-giessen.de.
F LimbergKlinik für Anästhesiologie, Operative Intensivmedizin und Schmerztherapie, Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen, Rudolf-Buchheim-Str. 7, 35385, Gießen, Deutschland.
S T W MannKlinik für Orthopädie, Zentralklinik Bad Berka, Bad Berka, Deutschland.
S LittleKlinik für Anästhesiologie, Operative Intensivmedizin und Schmerztherapie, Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen, Rudolf-Buchheim-Str. 7, 35385, Gießen, Deutschland.
M MüllerKlinik für Anästhesiologie, Operative Intensivmedizin und Schmerztherapie, Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen, Rudolf-Buchheim-Str. 7, 35385, Gießen, Deutschland.
M SanderKlinik für Anästhesiologie, Operative Intensivmedizin und Schmerztherapie, Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen, Rudolf-Buchheim-Str. 7, 35385, Gießen, Deutschland.
R RöhrigMedizinische Informatik, Carl von Ossietzky Universität, Oldenburg, Deutschland.
Universitätsklinikum Gießen und Marburg · DECarl von Ossietzky Universität Oldenburg · DEZentralklinik Bad Berka · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveFor emergency medicine personnel (EMP), there is little evidence concerning the adequate timing for refresher courses to maintain routine in the application of extraglottic airways. The aim of this study was to evaluate the efficacy and long-term results of a simulator-based education concept teaching the basic airway management skills with extraglottic airways for EMP and also to draw conclusions concerning the adequate time interval for refresher courses.

methodsBy use of an explorative, prospective simulator-study with nonphysician EMP, airway management skills using the Larynxmaske Supreme® (LMA‑S) after an introduction lecture were examined. The application of an endotracheal tube (ETT) served as control. Time for preparation of the airway devices, insertion success, and resulting apnea time were assessed immediately after the first introduction lecture (t1) and unannounced 9-12 months thereafter (t2).

resultsComparison of the times for preparation of the LMA‑S at t1 and t2 demonstrated similar results. After the introduction lecture, all paramedics were able to insert the LMA‑S successfully after maximal 2 attempts; 9-12 months later success rates with the LMA‑S were unchanged. Apnea time during airway management was shorter with the LMA‑S compared to the ETT (p < 0.01). Times needed for preparation of the airway devices were similar.

conclusionThe results of this simulator study indicate that a standardized introduction lecture is appropriate to ensure long-lasting procedural skills up to 12 months, so that subsequent refresher courses in basic airway management with the LMA‑S once a year may be adequate. A simulator-based education in basic airway management skills with extraglottic airways is recommended for facilitation of further clinical education according to the current guidelines.

Indexed as

Computer SimulationEducation, Medical, ContinuingLaryngeal MasksAirway ManagementEmergenciesFollow-Up StudiesHumansIntubation, IntratrachealProspective StudiesTeachingEmergency medical techniciansLaryngeal maskMedical educationPatient safetySimulation training

Identifiers

PMID29644401
OpenAlexW2796616923

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.