Evidence map›Paper›PMID 29642593›Full record

ArticleSensors (Basel, Switzerland)2018

Measuring the Human Ultra-Weak Photon Emission Distribution Using an Electron-Multiplying, Charge-Coupled Device as a Sensor.

Fernando Ortega-Ojeda, Matías Calcerrada, Alejandro Ferrero, Joaquín Campos, Carmen Garcia-Ruiz

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Fernando Ortega-OjedaDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Multipurpose Building of Chemistry, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain. fernando.ortega@uah.es.
Matías CalcerradaDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Multipurpose Building of Chemistry, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain. matias.calcerrada@uah.es.
Alejandro FerreroInstitute of Optics "Daza de Valdés", IO-CSIC, Calle Serrano 121, 28006 Madrid, Spain. alejandro.ferrero@csic.es.
Joaquín CamposInstitute of Optics "Daza de Valdés", IO-CSIC, Calle Serrano 121, 28006 Madrid, Spain. joaquin.campos@uah.es.
Carmen Garcia-RuizDepartment of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Multipurpose Building of Chemistry, University of Alcalá, Alcalá de Henares, 28871 Madrid, Spain. carmen.gruiz@uah.es.
Universidad de Alcalá · ESInstituto de Óptica "Daza de Valdés" · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultra-weak photon emission (UPE) is the spontaneous emission from living systems mainly attributed to oxidation reactions, in which reactive oxygen species (ROS) may play a major role. Given the capability of the next-generation electron-multiplying CCD (EMCCD) sensors and the easy use of liquid crystal tunable filters (LCTF), the aim of this work was to explore the potential of a simple UPE spectrometer to measure the UPE from a human hand. Thus, an easy setup was configured based on a dark box for inserting the subject's hand prior to LCTF as a monochromator and an EMCCD sensor working in the full vertical binning mode (FVB) as a spectra detector. Under controlled conditions, both dark signals and left hand UPE were acquired by registering the UPE intensity at different selected wavelengths (400, 450, 500, 550, 600, 650, and 700 nm) during a period of 10 min each. Then, spurious signals were filtered out by ignoring the pixels whose values were clearly outside of the Gaussian distribution, and the dark signal was subtracted from the subject hand signal. The stepped spectrum with a peak of approximately 880 photons at 500 nm had a shape that agreed somewhat with previous reports, and agrees with previous UPE research that reported UPE from 420 to 570 nm, or 260 to 800 nm, with a range from 1 to 1000 photons s

Indexed as

electron multiplying charge coupled device sensorliquid crystal tunable filtermeasurementspectrometerultra-weak photon emission

Identifiers

PMID29642593
PMCPMC5948505
OpenAlexW2797018767

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.