Evidence map›Paper›PMID 29641226›Full record

ArticleThe British journal of radiology2018

The impact of contrast-enhanced spectral mammogram (CESM) and three-dimensional breast ultrasound (3DUS) on the characterization of the disease extend in cancer patients.

Maha Hussien Helal, Sahar Mahmoud Mansour, Lamia Adel Salaleldin, Basma Mohamed Alkalaawy, Dorria Saleh Salem, Nadia Mahmoud Mokhtar

Abstract read
In one paragraph

Article in The British journal of radiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.7field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Maha Hussien Helal1 Department of Radiology, Women's Imaging Unit, National Cancer Institute, Cairo University , Cairo , Egypt.
Sahar Mahmoud Mansour2 Department of Radiology, Women's Imaging Unit, Kasr-El Ainy Hospital, Cairo University , Cairo , Egypt.
Lamia Adel Salaleldin2 Department of Radiology, Women's Imaging Unit, Kasr-El Ainy Hospital, Cairo University , Cairo , Egypt.
Basma Mohamed Alkalaawy2 Department of Radiology, Women's Imaging Unit, Kasr-El Ainy Hospital, Cairo University , Cairo , Egypt.
Dorria Saleh Salem2 Department of Radiology, Women's Imaging Unit, Kasr-El Ainy Hospital, Cairo University , Cairo , Egypt.
Nadia Mahmoud Mokhtar
Cairo University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe main importance of imaging breast cancer is to guide conservative surgeries. In this study, we evaluated the role of contrast-enhanced spectral mammogram (CESM) in correlation with three-dimensional (3D) breast ultrasound in characterizing the extension of the intramammary cancer in view of the: (i) the size of the main tumor, (ii) the multiplicity of the breast cancer, and (iii) the peri-tumoral stromal involvement (i.e. free or intraductal extension of the cancer).

methodsThe study is a prospective analysis that included 300 breast masses proved to be malignant. The masses were evaluated for their size, multiplicity and surrounding stromal involvement. Contrast-based mammography performed with low (22-33 kVp) and high (44-49 kVp) energy exposures that were taken after i.v. injection of contrast agent and followed by bilateral 3D breast ultrasound. Operative data were the gold standard reference.

resultsThere was no significant difference between the sizes of the included cancers as measured by CESM and 3D ultrasound and that measured at the pathological analysis. CESM showed higher accuracy (32.7%, n = 98) than 3D ultrasound (24.7%, n = 74) in the size agreement within 5% range. CESM was the most accurate modality (94%, n = 282) in detecting tumor multiplicity, followed by traditional sonomammogram (88%, n = 264), then 3D breast ultrasound (84%, n = 252). Intraductal extension of the breast cancer was best evaluated by the 3D ultrasound with an accuracy value of 98% (n = 294) compared to only 60% (n = 180) by CESM.

conclusionCESM is a recommended investigation in breast cancer to increase the accuracy of size measurement and the detection of multiple tumors. The addition of 3D ultrasound can enhance the detection of intraductal extension. Advances in knowledge: Choice of conservative breast surgery vs mastectomy is still a debate. We used an advanced, contrast-based, application of the mammogram: CESM and a non-invasive 3D breast ultrasound in the assessment of the local extension of the breast cancer regarding size, perifocal stromal infiltration and multiplicity to guide the selection of proper management in proved cases of breast cancer.

Indexed as

Imaging, Three-DimensionalAdultAgedBreast NeoplasmsContrast MediaFemaleHumansMammographyMiddle AgedNeoplasm InvasivenessNeoplasm StagingProspective StudiesTumor BurdenUltrasonography, MammaryContrast Media

Identifiers

PMID29641226
PMCPMC6221789
OpenAlexW2797871950

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked