Evidence map›Paper›PMID 29634750›Full record

ArticlePloS one2018

A fluidics-based impact sensor.

Daigo Takahashi, Keisuke Hara, Taiji Okano, Hiroaki Suzuki

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Daigo TakahashiFaculty of Science and Engineering, Chuo University, Tokyo, Japan.
Keisuke HaraFaculty of Science and Engineering, Chuo University, Tokyo, Japan.
Taiji OkanoFaculty of Science and Engineering, Chuo University, Tokyo, Japan.
Hiroaki SuzukiFaculty of Science and Engineering, Chuo University, Tokyo, Japan.ORCID 0000-0002-8899-0955
Chuo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microelectromechanical systems (MEMS)-based high-performance accelerometers are ubiquitously used in various electronic devices. However, there is an existing need to detect physical impacts using low-cost devices with no electronic circuits or a battery. We designed and fabricated an impact sensor prototype using a commercial stereolithography apparatus that only consists of a plastic housing and working fluids. The sensor device responds to the instantaneous acceleration (impact) by deformation and pinch off of a water droplet that is suspended in oil in a sensor cavity. We tested the various geometrical and physical parameters of the impact sensor to identify their relations to threshold acceleration values. We show that the state diagram that is plotted against the dimensionless Archimedes and Bond numbers adequately describes the response of the proposed sensor.

Indexed as

AccelerationBiosensing TechniquesEquipment DesignHumansMicro-Electrical-Mechanical Systems

Identifiers

PMID29634750
PMCPMC5892937
OpenAlexW2797346575

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked