SynthesisThe Cochrane database of systematic reviews2018
Optical correction of refractive error for preventing and treating eye symptoms in computer users.
Synthesis in The Cochrane database of systematic reviews, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.
- Optical correction of refractive error for preventing and treating eye symptoms in computer users.The Cochrane database of systematic reviews · 2018Pooled it
- The influence of large-diameter multifocal contact lens on ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes.Scientific reports · 2023Trial
- Is critical flicker-fusion frequency a valid measure of visual fatigue? A post-hoc analysis of a double-masked randomised controlled trial.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2023Trial
- Seasonal Effects on Corneal Densitometry and Haze After Mitomycin C-Assisted Photorefractive Keratectomy.Journal of clinical medicine · 2026Article
- Total score of the computer vision syndrome questionnaire predicts refractive errors and binocular vision anomalies.International journal of ophthalmology · 2026Article
- Binocular vision disorders and refractive errors on university students' quality of life.International journal of ophthalmology · 2025Article
- Article
- Headache in the Workplace: Analysis of Factors Influencing Headaches in Terms of Productivity and Health.International journal of environmental research and public health · 2022Article
- Anti-Fatigue Glasses Based on Microprisms for Preventing Eyestrain.Sensors (Basel, Switzerland) · 2022Article
- The Effect of Lockdown Due to the COVID-19 Pandemic on Digital Eye Strain Symptoms Among the General Population: A Cross-Sectional Survey.Frontiers in public health · 2022Article
- Does the Accuracy and Repeatability of Refractive Error Estimates Depend on the Measurement Principle of Autorefractors?Translational vision science & technology · 2021Article
- Functional Neuroanatomy of the Human Accommodation Response to an "E" Target Varying from -3 to -6 Diopters.Frontiers in integrative neuroscience · 2020Article
- Magnitude and Determinants of Computer Vision Syndrome among College Students at a Saudi University.Middle East African journal of ophthalmologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundComputer users frequently complain about problems with seeing and functioning of the eyes. Asthenopia is a term generally used to describe symptoms related to (prolonged) use of the eyes like ocular fatigue, headache, pain or aching around the eyes, and burning and itchiness of the eyelids. The prevalence of asthenopia during or after work on a computer ranges from 46.3% to 68.5%. Uncorrected or under-corrected refractive error can contribute to the development of asthenopia. A refractive error is an error in the focusing of light by the eye and can lead to reduced visual acuity. There are various possibilities for optical correction of refractive errors including eyeglasses, contact lenses and refractive surgery.
objectivesTo examine the evidence on the effectiveness, safety and applicability of optical correction of refractive error for reducing and preventing eye symptoms in computer users. SEARCH
methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL); PubMed; Embase; Web of Science; and OSH update, all to 20 December 2017. Additionally, we searched trial registries and checked references of included studies. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and quasi-randomised trials of interventions evaluating optical correction for computer workers with refractive error for preventing or treating asthenopia and their effect on health related quality of life. DATA COLLECTION AND ANALYSIS: Two authors independently assessed study eligibility and risk of bias, and extracted data. Where appropriate, we combined studies in a meta-analysis. MAIN
resultsWe included eight studies with 381 participants. Three were parallel group RCTs, three were cross-over RCTs and two were quasi-randomised cross-over trials. All studies evaluated eyeglasses, there were no studies that evaluated contact lenses or surgery. Seven studies evaluated computer glasses with at least one focal area for the distance of the computer screen with or without additional focal areas in presbyopic persons. Six studies compared computer glasses to other types of glasses; and one study compared them to an ergonomic workplace assessment. The eighth study compared optimal correction of refractive error with the actual spectacle correction in use. Two studies evaluated computer glasses in persons with asthenopia but for the others the glasses were offered to all workers regardless of symptoms. The risk of bias was unclear in five, high in two and low in one study. Asthenopia was measured as eyestrain or a summary score of symptoms but there were no studies on health-related quality of life. Adverse events were measured as headache, nausea or dizziness. Median asthenopia scores at baseline were about 30% of the maximum possible score.Progressive computer glasses versus monofocal glassesOne study found no considerable difference in asthenopia between various progressive computer glasses and monofocal computer glasses after one-year follow-up (mean difference (MD) change scores 0.23, 95% confidence interval (CI) -5.0 to 5.4 on a 100 mm VAS scale, low quality evidence). For headache the results were in favour of progressive glasses.Progressive computer glasses with an intermediate focus in the upper part of the glasses versus other glassesIn two studies progressive computer glasses with intermediate focus led to a small decrease in asthenopia symptoms (SMD -0.49, 95% CI -0.75 to -0.23, low-quality evidence) but not in headache score in the short-term compared to general purpose progressive glasses. There were similar small decreases in dizziness. At medium term follow-up, in one study the effect size was not statistically significant (SMD -0.64, 95% CI -1.40 to 0.12). The study did not assess adverse events.Another study found no considerable difference in asthenopia between progressive computer glasses and monofocal computer glasses after one-year follow-up (MD change scores 1.44, 95% CI -6.95 to 9.83 on a 100 mm VAS scale, very low quality evidence). For headache the results were inconsistent.Progressive computer glasses with far-distance focus in the upper part of the glasses versus other glassesOne study found no considerable difference in number of persons with asthenopia between progressive computer glasses with far-distance focus and bifocal computer glasses after four weeks' follow-up (OR 1.00, 95% CI 0.40 to 2.50, very low quality evidence). The number of persons with headache, nausea and dizziness was also not different between groups.Another study found no considerable difference in asthenopia between progressive computer glasses with far-distance focus and monofocal computer glasses after one-year follow-up (MD change scores -1.79, 95% CI -11.60 to 8.02 on a 100 mm VAS scale, very low quality evidence). The effects on headaches were inconsistent.One study found no difference between progressive far-distance focus computer glasses and trifocal glasses in effect on eyestrain severity (MD -0.50, 95% CI -1.07 to 0.07, very low quality evidence) or on eyestrain frequency (MD -0.75, 95% CI -1.61 to 0.11, very low quality evidence).Progressive computer glasses versus ergonomic assessment with habitual (computer) glassesOne study found that computer glasses optimised for individual needs reduced asthenopia sum score more than an ergonomic assessment and habitual (computer) glasses (MD -8.9, 95% CI -16.47 to -1.33, scale 0 to 140, very low quality evidence) but there was no effect on the frequency of eyestrain (OR 1.08, 95% CI 0.38 to 3.11, very low quality evidence).We rated the quality of the evidence as low or very low due to risk of bias in the included studies, inconsistency in the results and imprecision. AUTHORS'
conclusionsThere is low to very low quality evidence that providing computer users with progressive computer glasses does not lead to a considerable decrease in problems with the eyes or headaches compared to other computer glasses. Progressive computer glasses might be slightly better than progressive glasses for daily use in the short term but not in the intermediate term and there is no data on long-term follow-up. The quality of the evidence is low or very low and therefore we are uncertain about this conclusion. Larger studies with several hundreds of participants are needed with proper randomisation, validated outcome measurement methods, and longer follow-up of at least one year to improve the quality of the evidence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.