Evidence map›Paper›PMID 29633609›Full record

ArticleJournal of biomedical optics2018

Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices: emulation and evaluation of multispectral imaging systems.

Rolf B Saager, Melissa L Baldado, Rebecca A Rowland, Kristen M Kelly, Anthony J Durkin

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. [An optical parameter imaging system with profile information fusion].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2022
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rolf B SaagerUniversity of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
Melissa L BaldadoUniversity of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
Rebecca A RowlandUniversity of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
Kristen M KellyUniversity of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
Anthony J DurkinUniversity of California, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.

Funding

University of California Health Participation in the National COVID Cohort Collaborative (N3C)UL1TR001414 · NCATS · UNIVERSITY OF CALIFORNIA-IRVINE · PI COOPER, DAN M, VILAIN, ERIC J. · 2015 to 2023
$35.1M
Virtual Photonocs TechnologiesP41EB015890 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI DURKIN, ANTHONY · 2012 to 2017
$7.0M
Spatial Frequency Domain Imaging for Burn Wound Severity AssessmentR01GM108634 · NIGMS · UNIVERSITY OF CALIFORNIA-IRVINE · PI DURKIN, ANTHONY J · 2014 to 2023
$2.8M
Quantitative multiphoton microscopy for non-invasive diagnosis of melanomaR01CA195466 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI KELLY, KRISTEN M, TROMBERG, BRUCE J. · 2016 to 2018
$825k
NCATS NIH HHS UL1 TR001414NCI NIH HHS R01 CA195466NIBIB NIH HHS P41 EB015890NIGMS NIH HHS R01 GM108634
6 · The paper itself

Abstract

With recent proliferation in compact and/or low-cost clinical multispectral imaging approaches and commercially available components, questions remain whether they adequately capture the requisite spectral content of their applications. We present a method to emulate the spectral range and resolution of a variety of multispectral imagers, based on in-vivo data acquired from spatial frequency domain spectroscopy (SFDS). This approach simulates spectral responses over 400 to 1100 nm. Comparing emulated data with full SFDS spectra of in-vivo tissue affords the opportunity to evaluate whether the sparse spectral content of these imagers can (1) account for all sources of optical contrast present (completeness) and (2) robustly separate and quantify sources of optical contrast (crosstalk). We validate the approach over a range of tissue-simulating phantoms, comparing the SFDS-based emulated spectra against measurements from an independently characterized multispectral imager. Emulated results match the imager across all phantoms (<3  %   absorption, <1  %   reduced scattering). In-vivo test cases (burn wounds and photoaging) illustrate how SFDS can be used to evaluate different multispectral imagers. This approach provides an in-vivo measurement method to evaluate the performance of multispectral imagers specific to their targeted clinical applications and can assist in the design and optimization of new spectral imaging devices.

Indexed as

AdultAnimalsBurnsCarotenoidsFemaleHemoglobinsHumansMaleMelaninsMiddle AgedMultimodal ImagingOptical ImagingPhantoms, ImagingRatsSkinSkin AgingCarotenoidsHemoglobinsMelaninsmultispectral imagingreflectance spectroscopytissue optics

Identifiers

PMID29633609
PMCPMC5890028

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.