Intraoperative Radiotherapy With INTRABEAM: Technical and Dosimetric Considerations.

Anil Sethi, Bahman Emami, William Small, Tarita O Thomas

Registry-linked trialAbstract read
In one paragraph

Article in Frontiers in oncology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02773966 (Intraoperative Radiotherapy During Kyphoplasty/Vertebroplasty), which is not on this map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02773966 phase3terminatednot on this map

Intraoperative Radiotherapy During Kyphoplasty/Vertebroplasty (Kypho-IORT) Versus EBRT in the Treatment of Painful Vertebral Metastases - a Randomized Prospective Phase III Study -

TypeinterventionalSponsorUniversitätsmedizin MannheimRan2017 to 2020Enrolled6ConditionsMetastasisArmsKypho-IORT, EBRT
3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anil SethiLoyola University Medical Center, Maywood, IL, United States.
Bahman EmamiLoyola University Medical Center, Maywood, IL, United States.
William SmallLoyola University Medical Center, Maywood, IL, United States.
Tarita O ThomasLoyola University Medical Center, Maywood, IL, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe evaluate dose characteristics and clinical applications of treatment accessories used in intraoperative radiotherapy (IORT) and make site-specific recommendations for their optimal use. METHODS AND MATERIALS: Dose measurements were performed for a low energy (50 kV) X-ray INTRABEAM source. For spherical, flat, surface, and needle applicators, the following dosimetric parameters were measured: depth-dose (DD) profiles, surface dose (Ds), output factors (OF), and target dose homogeneity (DH). Optical density versus exposure calibration films were employed to obtain 2-dimensional dose distributions in planes parallel and perpendicular to beam direction. Film results were verified

resultsSpherical applicators are commonly used for treating the inner-surface of breast lumpectomy cavity. Flat and surface applicators provide uniform planar dose for head and neck, abdomen, and pelvis targets. Needle applicators are designed for kypho-IORT of spinal metastasis. Typically, larger applicators produce a more homogeneous target dose region with lower surface dose, but require longer treatment times. For 4-cm diameter spherical, flat, and surface applicators, dose rates (DR) at their respective prescription points were found to be: 0.8, 0.3, and 2.2 Gy/min, respectively. The DR for a needle applicator was 7.04 Gy/min at 5 mm distance from the applicator surface. Overall, film results were in excellent agreement with ion-chamber data.

conclusionIORT may be delivered with a variety of site-specific applicators. Appropriate applicator use is paramount for safe, effective, and efficient IORT delivery. Results of this study should help clinicians assure optimized target dose coverage and reduced normal tissue exposure.

Indexed as

dosimetryflatintrabeamsphericalsurface applicators

Identifiers

PMID29632850
PMCPMC5879442

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.