ArticleJournal of clinical orthopaedics and trauma
Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?
Article in Journal of clinical orthopaedics and trauma. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Role of Image-Free Robotic-Assisted Technology in Enhancing Accuracy of Implant Sizing for Total Knee Arthroplasty.Cureus · 2024Article
- The Accuracy of CT-Based Three-Dimensional Templating in Predicting Implant Sizes in Patients Undergoing Robot-Assisted Total Knee Arthroplasty.Indian journal of orthopaedics · 2024Article
- Preoperative radiographic parameters in the case of using a narrow-version femoral implant in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2022Article
- A computational tool for automatic selection of total knee replacement implant size using X-ray images.Frontiers in bioengineering and biotechnology · 2022Article
- Challenges, controversies, and innovations in arthroplasty.Journal of clinical orthopaedics and traumaArticle
- Current status and challenges of Additive manufacturing in orthopaedics: An overview.Journal of clinical orthopaedics and traumaArticle
- Publication trends and knowledge mapping in 3D printing in orthopaedics.Journal of clinical orthopaedics and traumaReview
- Additive manufacturing applications in orthopaedics: A review.Journal of clinical orthopaedics and traumaReview
- Computed tomography based 3D printed patient specific blocks for total knee replacement.Journal of clinical orthopaedics and traumaReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of the study was to assess the accuracy of tibial and femoral component size prediction using computerised tomography (CT) based patient specific instruments in total knee arthroplasty.
methodsEighty-eight knees in 58 patients underwent total knee arthroplasty (TKA) using CT based patient specific instruments between March 2015 to April 2016. All patients were assessed for the pre operative femoral and tibial component sizes predicted by the CT-based pre-operative plan. These sizes were compared with the actually implanted sizes during surgery, and the results were assessed. The data were evaluated using Wilcoxon signed rank tests, and p value set at <0.05 for significance.
resultsApproximately 72% predicted tibia sizes matched the final implanted sizes whereas 66% femoral implants matched their pre-operative predicted sizes. The difference in the tibial implant size was not statistically significant (p-value > 0.05). However, the difference in the femoral size was statistically significant (p-value 0.009). The downsizing of the tibial component was needed in 14.8% knees whereas upsizing was required in 13.6% of the knees. At the femoral side, 22.7% components required downsizing at the time of implantation as compared to 11.4% components wherein a bigger component was used.
conclusionsWe conclude that size prediction using CT-based technology for patient specific instrumentation is not fool proof. The size prediction accuracy for femoral and tibial components at 66% and 72% are low and cannot be relied upon at present. The patient specific technology using CT scan based jigs holds promise for the future, needs refining and fine tuning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.