Evidence map›Paper›PMID 29628217›Full record

ArticleMedical engineering & physics2018

Development and characterization of a point-of care rate-based transcutaneous respiratory status monitor.

Xudong Ge, Prosper Adangwa, Ja Young Lim, Yordan Kostov, Leah Tolosa, Richard Pierson, Daniel Herr, Govind Rao

Abstract read
In one paragraph

Article in Medical engineering & physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. What do masks mask? A study on transdermal COMedical engineering & physics · 2021
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xudong GeCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA. Electronic address: xge1@umbc.edu.
Prosper AdangwaCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA.
Ja Young LimCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA.
Yordan KostovCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA.
Leah TolosaCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA.
Richard PiersonDepartment of Surgery, University of Maryland School of Medicine, 22 S. Greene Street, Baltimore, Maryland 21201, USA.
Daniel HerrDepartment of Surgery, University of Maryland School of Medicine, 22 S. Greene Street, Baltimore, Maryland 21201, USA.
Govind RaoCenter for Advanced Sensor Technology, University of Maryland, Baltimore County, 1000 Hilltop Circle, Baltimore, Maryland 21250, USA. Electronic address: grao@umbc.edu.

Funding

A wearable asthma trigger monitoring system with integrated physiological monitorU01EB021952 · NIBIB · UNIVERSITY OF MARYLAND BALTIMORE COUNTY · PI MEURET, ALICIA ESPERANZA, RAO, GOVIND · 2015 to 2015
$2.0M
Non-invasive neonatal respiration monitorR41HD072901 · NICHD · FLUOROMETRIX CORPORATION · PI GE, XUDONG, POTTS, RUSSELL O · 2012 to 2013
$495k
NIBIB NIH HHS U01 EB021952NICHD NIH HHS R41 HD072901
6 · The paper itself

Abstract

Blood gas measurements provide vital clinical information in critical care. The current "gold standard" for blood gas measurements involves obtaining blood samples, which can be painful and can lead to bleeding, thrombus formation, or infection. Mass transfer equilibrium-based transcutaneous blood gas monitors have been used since the 1970s, but they require heating the skin to ≥42 °C to speed up the transcutaneous gas diffusion. Thus, these devices have a potential risk for skin burns. Here we report a new generation of noninvasive device for respiratory status assessment. Instead of waiting for mass transfer equilibrium, the blood gas levels are monitored by measuring the transcutaneous diffusion rate, which is proportional to blood gas concentration. The startup time of this device is almost independent of skin temperature, so the measurement can be made at any body temperature. The test results show that this device can track the blood gas levels quickly even at normal body temperature.

Indexed as

Point-of-Care SystemsBlood Gas Monitoring, TranscutaneousCarbon DioxideEquipment DesignSignal-To-Noise RatioCarbon DioxideBlood gasMonitorNoninvasiveRespirationSensorTranscutaneous

Identifiers

PMID29628217
PMCPMC5932206

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.