ArticleMedical engineering & physics2018
Development and characterization of a point-of care rate-based transcutaneous respiratory status monitor.
Article in Medical engineering & physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- A Direct Current-to-Digital Converter IC for Luminescence-Based Detection Toward an Energy Efficient Transcutaneous Carbon Dioxide Sensor Wearable.IEEE open journal of the Solid-State Circuits Society · 2025Article
- Recent Technologies for Transcutaneous Oxygen and Carbon Dioxide Monitoring.Diagnostics (Basel, Switzerland) · 2024Review
- Dynamic Modeling of Carbon Dioxide Transport through the Skin Using a Capnometry Wristband.Sensors (Basel, Switzerland) · 2023Article
- Noninvasive carbon dioxide monitoring in pediatric patients undergoing laparoscopic surgery: transcutaneous vs. end-tidal techniques.BMC pediatrics · 2023Article
- A novel approach to noninvasive monitoring of dissolved carbon dioxide in small-scale cell culture processes.Frontiers in bioengineering and biotechnology · 2022Article
- Carbon Dioxide Sensing-Biomedical Applications to Human Subjects.Sensors (Basel, Switzerland) · 2021Review
- What do masks mask? A study on transdermal COMedical engineering & physics · 2021Article
- Compliance of a microstructured, soft sampling device for transcutaneous blood gas monitoring.RSC advances · 2020Article
- Real-time dissolved carbon dioxide monitoring I: Application of a novel in situ sensor for COBiotechnology and bioengineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Blood gas measurements provide vital clinical information in critical care. The current "gold standard" for blood gas measurements involves obtaining blood samples, which can be painful and can lead to bleeding, thrombus formation, or infection. Mass transfer equilibrium-based transcutaneous blood gas monitors have been used since the 1970s, but they require heating the skin to ≥42 °C to speed up the transcutaneous gas diffusion. Thus, these devices have a potential risk for skin burns. Here we report a new generation of noninvasive device for respiratory status assessment. Instead of waiting for mass transfer equilibrium, the blood gas levels are monitored by measuring the transcutaneous diffusion rate, which is proportional to blood gas concentration. The startup time of this device is almost independent of skin temperature, so the measurement can be made at any body temperature. The test results show that this device can track the blood gas levels quickly even at normal body temperature.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials