SynthesisMedicine2018
A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence.
Synthesis in Medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05682989 (Evaluation of Efficacy and Safety of Urogynecology Synthetic Mesh Surgery in Women With Pelvic Organ Prolapse), which is not on this map. Cited by 9 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Evaluation of Efficacy and Safety of Urogynecology Synthetic Mesh Surgery in Women With Pelvic Organ Prolapse
Who cites it
9 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.
- Single-incision sling operations for urinary incontinence in women.The Cochrane database of systematic reviews · 2023Pooled it
- Pooled it
- Trial
- Attitudes towards stress urinary incontinence surgery in Ireland: navigating the pause on mid-urethral sling use.Irish journal of medical science · 2025Article
- Precision in Practice: The Critical Role of Mesh and Procedure Type Specification in Urogynecological Surgeries and Research.International urogynecology journal · 2024Article
- Single Incision Sling Surgery for Female Stress Urinary Incontinence: A Retrospective Cohort Single-Institution Study.Journal of clinical medicine · 2024Article
- Three-year patient-reported outcomes of single-incision versus transobturator slings for female stress urinary incontinence are equivalent.International urogynecology journal · 2023Article
- Review
- Evaluation of efficacy and safety of single-incision sling versus transobturator sling in women with stress incontinence and intrinsic sphincter deficiency.International urogynecology journal · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTo assess the current evidence of effectiveness and safety of single-incision mini-slings (MiniArc) versus transobturator midurethral slings in the management of female stress urinary incontinence (SUI).
methodsA systematic search was performed from the electronic databases including PubMed, EMBASE, and Cochrane Library by November 2017. Using RevMan5.3 statistical software, the primary outcomes including subject and objective cure rates at 6 to 24 months follow-up were evaluated. Meanwhile, analysis was also performed for comparing the secondary outcomes such as peri- and postoperative complications, operative data, and quality of life.
resultsSix randomized controlled trials (RCTs) and 6 retrospective cohort studies involving 1794 patients with SUI were analyzed based on the inclusion criteria. On the basis of our analysis, MiniArc was proven to have a noninferior clinical efficacy compared with transobturator midurethral slings with respect to the objective cure rate (risk ratio [RR] = 0.98, 95% confidence interval [CI] 0.94-1.03, P = .43) and subjective cure rate (RR = 0.97, 95% CI 0.91-1. 04, P = .38). In addition, pooled analysis showed that MiniArc had significantly lower postoperative pain scores (mean difference [MD] = -1.70, 95% CI -3.17 to -0.23, P = .02) and less postoperative groin pain (RR = 0.42, 95% CI 0.18-0.98, P = .04). Moreover, the MiniArc group also had a significantly shorter operation time (MD = -6.12, 95% CI -8.61 to -3.64, P < .001), less blood loss (MD = -16.67, 95% CI -26.29 to -7.05, P < .001), shorter in-patient stay (MD = 1.30, 95% CI -1.74 to -0.86, P < .001), and less urinary retention risk (RR = 1.15, 95% CI 0.46-2.87, P = .77). However, overall evidence was insufficient to suggest a statistically significant difference in the adverse event profile for MiniArc compared with transobturator slings.
conclusionsThis meta-analysis indicates that MiniArc is an effective method treating SUI. When compared with transobturator slings, it not only has a similar high cure rates, but also is associated with shorter operation time, less blood loss, more favorable recovery time, lower postoperative pain scores, less postoperative groin pain, less urinary retention, and absence of a visible wound. However, the findings of this study should be further confirmed by well-designed prospective RCTs with a larger patient series.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.