Evidence map›Paper›PMID 29620432›Full record

ArticlePublic health reports (Washington, D.C. : 1974)

Identifying Algorithms to Improve the Accuracy of Unverified Diagnosis Codes for Birth Defects.

Jason L Salemi, Rachel E Rutkowski, Jean Paul Tanner, Jennifer L Matas, Russell S Kirby

Abstract read
In one paragraph

Article in Public health reports (Washington, D.C. : 1974). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Implementation of the BC Congenital Anomalies Surveillance System (BCCASS).Canadian journal of public health = Revue canadienne de sante publique · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jason L Salemi1 Department of Family and Community Medicine, Baylor College of Medicine, Houston, TX, USA.
Rachel E Rutkowski2 Birth Defects Surveillance Program, Department of Community and Family Health, College of Public Health, University of South Florida, Tampa, FL, USA.
Jean Paul Tanner2 Birth Defects Surveillance Program, Department of Community and Family Health, College of Public Health, University of South Florida, Tampa, FL, USA.
Jennifer L Matas1 Department of Family and Community Medicine, Baylor College of Medicine, Houston, TX, USA.
Russell S Kirby2 Birth Defects Surveillance Program, Department of Community and Family Health, College of Public Health, University of South Florida, Tampa, FL, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesWe identified algorithms to improve the accuracy of passive surveillance programs for birth defects that rely on administrative diagnosis codes for case ascertainment and in situations where case confirmation via medical record review is not possible or is resource prohibitive.

methodsWe linked data from the 2009-2011 Florida Birth Defects Registry, a statewide, multisource, passive surveillance program, to an enhanced surveillance database with selected cases confirmed through medical record review. For each of 13 birth defects, we calculated the positive predictive value (PPV) to compare the accuracy of 4 algorithms that varied case definitions based on the number of diagnoses, medical encounters, and data sources in which the birth defect was identified. We also assessed the degree to which accuracy-improving algorithms would affect the Florida Birth Defects Registry's completeness of ascertainment.

resultsThe PPV generated by using the original Florida Birth Defects Registry case definition (ie, suspected cases confirmed by medical record review) was 94.2%. More restrictive case definition algorithms increased the PPV to between 97.5% (identified by 1 or more codes/encounters in 1 data source) and 99.2% (identified in >1 data source). Although PPVs varied by birth defect, alternative algorithms increased accuracy for all birth defects; however, alternative algorithms also resulted in failing to ascertain 58.3% to 81.9% of cases.

conclusionsWe found that surveillance programs that rely on unverified diagnosis codes can use algorithms to dramatically increase the accuracy of case finding, without having to review medical records. This can be important for etiologic studies. However, the use of increasingly restrictive case definition algorithms led to a decrease in completeness and the disproportionate exclusion of less severe cases, which could limit the widespread use of these approaches.

Indexed as

AlgorithmsData AccuracyCongenital AbnormalitiesDatabases, FactualFloridaHumansInfantInfant, NewbornInternational Classification of DiseasesMedical RecordsPatient DischargePopulation SurveillanceRegistriesaccuracybirth defectscongenital malformationspositive predictive valuesurveillance

Identifiers

PMID29620432
PMCPMC5958386

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.