Evidence map›Paper›PMID 29619557›Full record

Trial reportEuropean journal of pediatrics2018

Performance and skill retention of five supraglottic airway devices for the pediatric difficult airway in a manikin.

Johannes Kulnig, Lisa Füreder, Nicole Harrison, Michael Frass, Oliver Robak

Open access · hybridAbstract readClinical TrialComparative Study
In one paragraph

Trial report in European journal of pediatrics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Trial
  2. Article
  3. Evaluation of the New SingularityJournal of clinical medicine · 2022
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Johannes KulnigDepartment of Pediatrics, University Hospital Tulln, Karl-Landsteiner University of Health Sciences, Tulln, Austria.
Lisa FürederDepartment of Anaesthesia, General Intensive Care and Pain Medicine, Medical University of Vienna, Vienna, Austria.
Nicole HarrisonDepartment of Medicine I, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Michael FrassDepartment of Medicine I, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria.
Oliver RobakDepartment of Medicine I, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria. oliver.robak@meduniwien.ac.at.ORCID http://orcid.org/0000-0002-3238-194X
Medical University of Vienna · ATKarl Landsteiner University of Health Sciences · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Supraglottic airway devices (SADs) have been introduced to assist medical professionals in emergency situations with limited experience in securing airways via conventional endotracheal intubation (ETI). Literature on the use of SADs for securing an airway during pediatric critical settings is scarce, and there is a lack of studies comparing different SADs to each other and to conventional ETI. We conducted a study comparing five different SADs to ETI with regard to success rate, time to first ventilation, and personal rating in a pediatric manikin under simulated physiologic and pathologic airway conditions in 41 pediatricians of varying clinical experience and training. Only the AirQ, AuraG, and laryngeal tube (LT) were inserted within 30 s correctly by all participants under physiologic conditions. In tongue edema (TE), AirQ and LT had the highest success rate. In limited mobility of the cervical spine (CS), AirQ, AuraG, and LT again all were inserted within 30 s. In a multivariate analysis, factors influencing the success were experience with the respective device and level of medical education. Under TE conditions, there were significantly longer insertion times for the ETI, laryngeal mask airway (LMA), and EzT. Under CS conditions, there were significantly longer insertion times for the ETI, LMA, LT, and EzT. A multivariate analysis showed experience with the respective device to be the only factor of influence on time to first ventilation.

conclusionLT, AuraG, and AirQ were superior in providing fast and effective ventilation during simulated difficult airway situations in pediatricians. What is Known: • Supraglottic airway devices have been introduced for medical professionals who lack experience for managing difficult airway situations. • A variety of these devices have been developed so far, but not compared to each other yet. What is New: • We compared five different supraglottic airway devices with regard to success rate, time to first ventilation, and personal rating in a pediatric manikin under simulated physiologic and pathologic airway conditions. • Laryngeal tube, AuraG, and AirQ were superior in providing fast and effective ventilation during simulated difficult airway situations in pediatricians with varying clinical experience.

Indexed as

Clinical CompetenceEducation, Medical, ContinuingLaryngeal MasksManikinsRetention, PsychologySimulation TrainingAdultAustriaChildFemaleHumansMalePediatricsTime FactorsAirway managementDifficult airwayIntubationPediatricianSupraglottic airway

Identifiers

PMID29619557
PMCPMC5958163
OpenAlexW2795580405

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.