ArticleScience translational medicine2018
Battery-free, wireless sensors for full-body pressure and temperature mapping.
Article in Science translational medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 88 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
88 citing papers in PubMed, 338 citations in OpenAlex.
- Clinical applicable skin-interfaced thermal guiding sensor for warning perioperative abnormalities in core body temperature and blood perfusion rate.Nature communications · 2026Article
- A hemispherical latitude-gradient sensor for closed-loop monitoring and management of scoliosis correction.Science advances · 2026Article
- Flexible Multimodal Wearable Biosensors for Continuous Health Monitoring: Recent Advances and Challenges.Biosensors · 2026Review
- Dynamic Self-Healing Polymer Architectures for High-Performance Flexible Sensing.Advanced materials (Deerfield Beach, Fla.) · 2026Review
- Smart patches for healthcare industry: a review of emerging technologies, challenges, and developmental opportunities.Biomedical engineering online · 2026Review
- Skin-Integrated Soft Wearable XR Interfaces for Seamless and Realistic User Experience.Chemical reviews · 2025Review
- Large-area and soft magnetoelastic sensing for normal and shear stress distribution toward pressure injury prevention.Nature communications · 2025Article
- Photonic Nanomaterials for Wearable Health Solutions.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Lighting the Path to Precision Healthcare: Advances and Applications of Wearable Photonic Sensors.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- NFC/RFID-enabled wearables and implants for biomedical applications.Microsystems & nanoengineering · 2025Review
- Ultra-Sensitive Wireless Capacitive Nanocomposite-Based Pressure Sensors for Health Monitoring.Advanced materials technologies · 2025Article
- Flexible Tactile Sensing Systems: Challenges in Theoretical Research Transferring to Practical Applications.Nano-micro letters · 2025Review
- An Ultra-Robust, Highly Compressible Silk/Silver Nanowire Sponge-Based Wearable Pressure Sensor for Health Monitoring.Biosensors · 2025Article
- A Taxonomy of Pressure Sensors for Compression Garment Development.Sensors (Basel, Switzerland) · 2025Review
- Smart Dust for Chemical Mapping.Advanced materials (Deerfield Beach, Fla.) · 2025Review
- Contactless Braille sensing based on GaN optical devices integrated with epoxy lenses.Microsystems & nanoengineering · 2025Article
- Electrically-Shielded Coil-Enabled Battery-Free Wireless Sensing for Underwater Environmental Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Flexible Hybrid Integration Hall Angle Sensor Compatible with the CMOS Process.Sensors (Basel, Switzerland) · 2025Article
- Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems.Advanced materials (Deerfield Beach, Fla.) · 2024Review
- Nanocomposite Multimodal Sensor Array Integrated with Auxetic Structure for an Intelligent Biometrics System.Small (Weinheim an der Bergstrasse, Germany) · 2024Article
28 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
21 authors at 5 institutions in 3 countries.
Funding
Abstract
Thin, soft, skin-like sensors capable of precise, continuous measurements of physiological health have broad potential relevance to clinical health care. Use of sensors distributed over a wide area for full-body, spatiotemporal mapping of physiological processes would be a considerable advance for this field. We introduce materials, device designs, wireless power delivery and communication strategies, and overall system architectures for skin-like, battery-free sensors of temperature and pressure that can be used across the entire body. Combined experimental and theoretical investigations of the sensor operation and the modes for wireless addressing define the key features of these systems. Studies with human subjects in clinical sleep laboratories and in adjustable hospital beds demonstrate functionality of the sensors, with potential implications for monitoring of circadian cycles and mitigating risks for pressure-induced skin ulcers.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.