Evidence map›Paper›PMID 29616357›Full record

ArticleIntensive care medicine experimental2018

Preliminary experience on the safety and tolerability of mechanical "insufflation-exsufflation" in subjects with artificial airway.

Miguel Sánchez-García, Passio Santos, Gema Rodríguez-Trigo, Fernando Martínez-Sagasti, Tomás Fariña-González, Ángela Del Pino-Ramírez, Carlos Cardenal-Sánchez, Beatriz Busto-González, Mónica Requesens-Solera, Mercedes Nieto-Cabrera and 2 more

3 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Intensive care medicine experimental, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 12 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 2 pooled it
3.9field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06202859 naunknown statusnot on this mapstarted 2022, after this paper: background citation

Respiratory Physiotherapy as a Tool to Increase the Number of Solid Organ Donors

TypeinterventionalSponsorVall d'Hebron Institute ResearchRan2022 to 2025Enrolled160ConditionsLung Transplant FailureArmsMIE
NCT06310941 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Aspiration of Bronchial Secretions With Mechanical Insufflation-Exsufflation and Hypertonic Saline in Bacterial Nosocomial Tracheobronchitis and Pneumonia in Intubated Patients.

TypeinterventionalSponsorHospital San Carlos, MadridRan2026 to 2027Enrolled100ConditionsNosocomial Infection, Nosocomial Pneumonia, Tracheobronchitis, Mechanical Ventilation ComplicationArmsMechanical insufflation-exsufflation, Standard of Care, Hypertonic saline with hyaluronic acid
NCT06491017 narecruitingnot on this mapstarted 2026, after this paper: background citation

Effects of Mechanical Insufflation-Exsufflation With Optimized Settings on Suctioned Wet Mucus Volume During Invasive Ventilation

TypeinterventionalSponsorHospital Clinic of BarcelonaRan2026 to 2028Enrolled26ConditionsMucus Retention, Mechanical Ventilation ComplicationArmsMI-E Intervention protocol, Standard MI-E setting
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 2 syntheses or guidelines pooled it, 38 citations in OpenAlex.

  1. Pooled it
  2. Use of mechanical insufflation exsufflation and manual techniques in an intubated adult with COVID-19 positioned in prone-A case study.Physiotherapy research international : the journal for researchers and clinicians in physical therapy · 2022
    Pooled it
  3. Trial
  4. Trial
  5. Tracheostomy Decannulation Practices in Indian Intensive Care Units: A National Cross-sectional Survey of Intensive Care Unit Consultants.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Miguel Sánchez-GarcíaCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain. miguelsanchez.hcsc@gmail.com.ORCID http://orcid.org/0000-0002-8775-255X
Passio SantosPhysiotherapy and Rehabilitation Service, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Gema Rodríguez-TrigoService of Pulmonology, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Fernando Martínez-SagastiCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Tomás Fariña-GonzálezCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Ángela Del Pino-RamírezCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Carlos Cardenal-SánchezCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Beatriz Busto-GonzálezCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Mónica Requesens-SoleraCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Mercedes Nieto-CabreraCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Francisco Romero-RomeroCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Antonio Núñez-ReizCritical Care Department, Hospital Clínico San Carlos, c/Prof. Martín Lagos s/n, 28040, Madrid, Spain.
Hospital Clínico San Carlos · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCatheter suctioning of respiratory secretions in intubated subjects is limited to the proximal airway and associated with traumatic lesions to the mucosa and poor tolerance. "Mechanical insufflation-exsufflation" exerts positive pressure, followed by an abrupt drop to negative pressure. Potential advantages of this technique are aspiration of distal airway secretions, avoiding trauma, and improving tolerance.

methodsWe applied insufflation of 50 cmH

resultsMechanical insufflation-exsufflation was applied 26 times to 7 male and 6 female subjects requiring suctioning. Mean age was 62.6 ± 20 years and mean Apache II score 23.3 ± 7.4 points. At each session, a median of 2 (IQR 1; 2) cycles on median day of intubation 11.5 (IQR 6.25; 25.75) were performed. Mean insufflation tidal volume was 1043.6 ± 649.9 ml. No statistically significant differences were identified between baseline and post-procedure time points. Barotrauma, desaturation, atelectasis, hemoptysis, or other airway complication and hemodynamic complications were not detected. All, except one, of the mechanical insufflation-exsufflation sessions were productive, showing secretions in the proximal artificial airway, and were well tolerated.

conclusionsOur preliminary data suggest that mechanical insufflation-exsufflation may be safe and effective in patients with artificial airway. Safety and efficacy need to be confirmed in larger studies with different patient populations.

trial registrationEudraCT 2017-005201-13 (EU Clinical Trials Register).

Indexed as

Airway clearanceArtificial airwayEndotracheal aspirationEndotracheal intubationMechanical insufflation-exsufflationRespiratory tract secretionsSafetySecretion suctioning

Identifiers

PMID29616357
PMCPMC5882479
OpenAlexW2796570171

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.