ArticleJournal of anesthesia2018
Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System™ in patients undergoing abdominal aortic aneurysm surgery.
Article in Journal of anesthesia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 2 syntheses or guidelines pooled it, 19 citations in OpenAlex.
- Superior vena cava collapsibility index as a predictor of fluid responsiveness: a systematic review with meta-analysis.Anaesthesiology intensive therapy · 2024Pooled it
- Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.Journal of clinical monitoring and computing · 2020Pooled it
- A Novel Method for Cardiac Output and Vascular Parameters Estimation Using Peripheral Arterial Waveforms: Integrating Windkessel Model viaAnnals of biomedical engineering · 2026Article
- Continuous Non-Invasive Hemodynamic Monitoring in Cirrhotic Patients-Friend or Foe?Medicina (Kaunas, Lithuania) · 2025Article
- Article
- Intraoperative Hypotension Prediction-A Proactive Perioperative Hemodynamic Management-A Literature Review.Medicina (Kaunas, Lithuania) · 2023Review
- The Cardiac Power Index during Abdominal Open Aortic Surgery: Intraoperative Insights into the Cardiac Performance-A Retrospective Observational Analysis.Journal of personalized medicine · 2022Article
- The value of a superior vena cava collapsibility index measured with a miniaturized transoesophageal monoplane continuous echocardiography probe to predict fluid responsiveness compared to stroke volume variations in open major vascular surgery: a prospective cohort study.Journal of clinical monitoring and computing · 2020Article
- Update on the assessment of fluid responsiveness.Journal of anesthesia · 2020Article
- The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system™ and the Fick method in cardiac surgery patients.Journal of clinical monitoring and computing · 2019Observational
- Accuracy of non-invasive and minimally invasive hemodynamic monitoring: where do we stand?Annals of translational medicine · 2019Review
- Accuracy of the ClearSight™ system in patients undergoing abdominal aortic aneurysm surgery.Journal of anesthesia · 2019Article
- Disagreement in cardiac output measurements between fourth-generation FloTrac and critical care ultrasonography in patients with circulatory shock: a prospective observational study.Journal of intensive care · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe fourth-generation FloTrac/Vigileo™ improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery by comparing the FloTrac/Vigileo™-derived CI (CI
methodsTwenty-six patients undergoing elective AAA surgery were included in this study. CI
resultsIn the Bland-Altman analysis, CI
conclusionsThe degree of accuracy of the fourth-generation FloTrac/Vigileo™ in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo™ after aortic clamp was below the acceptable limit.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials