Evidence map›Paper›PMID 29615100›Full record

ArticleJournal of orthopaedic surgery and research2018

Ultrasonography or direct radiography? A comparison of two techniques to detect dorsal screw penetration after volar plate fixation.

Yunus Oc, Bekir Eray Kilinc, Anıl Gulcu, Ali Varol, Rodi Ertugrul, Adnan Kara

Open access · goldAbstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Yunus OcSisli Hamidiye Etfal Training and Research Hospital, Halaskargazi Cad., Etfal Sk, Şişli, 34371, Istanbul, Turkey.
Bekir Eray KilincGolhisar State Hospital, Fatih Mahallesi, Cumhuriyet Cad, 15400, Gölhisar, Burdur, Turkey. dreraykilinc@gmail.com.
Anıl GulcuAlaaddin Keykubat University, Kestel Mahallesi, Konya Çimento Caddesi No: 80, Alanya, 07450, Antalya, Turkey.
Ali VarolSilopi State Hospital, Yenişehir Mah, İpek Yolu Üzeri, 73400, Silopi, Şırnak, Turkey.
Rodi ErtugrulKilis State Hospital, Kazım Karabekir Mahallesi, Abdullah Gül Bulv.Çevre Yolu Üzeri: 2/1, 79000, Kilis, Turkey.
Adnan KaraMedipol University, Göztepe Mahallesi, Metin Sk. No: 4, Bağcılar, 34214, Istanbul, Turkey.
Alanya Hamdullah Emin Pasa University · TRIstanbul Medipol University · TRKilis 7 Aralık University · TRŞişli Etfal Eğitim ve Araştırma Hastanesi · TRSivas State Hospital · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComplications related to extensor tendons have begun to increase with the use of volar plates in the treatment of distal radius fractures. In this study, we aimed to compare four-plane radiography and ultrasonography in the evaluation of dorsal cortex screw penetration following volar plate fixation.

methodsWe recruited 47 patients (33 males, 14 females, mean age 37.4 years; range 18-58 years). To evaluate dorsal screw penetration in all patients, we performed radiographs at 45° pronation, 45° supination and obtained dorsal tangential graphs at maximum palmar flexion, and a wrist lateral radiograph. Wrist ultrasonography was performed in all patients.

resultsDorsal screw penetration was detected in 12 of the 47 patients undergoing VLP application. While there was > 2 mm screw penetration in seven patients, there was < 2 mm screw penetration in five patients. On four-plane radiographs, screw penetration > 2 mm was detected in seven patients and screw penetration < 2 mm was detected in two patients. On four-plane radiography, dorsal screw penetration was not detected in three out of five patients, who were shown to have < 2 mm screw penetration by ultrasonography. In addition to perioperative four-plane radiographs are also required to detect dorsal cortex penetration in patients undergoing VLP due to distal radius fracture. However, the detection of screw penetrations < 2 mm is more likely with ultrasonography compared to four-plane radiography.

conclusionWe recommend that dorsal cortex screw penetration should be evaluated with perioperative ultrasonography.

trial registrationResearch Registry, researchregistry3344 , Registered 10 January 2017.

Indexed as

AdolescentAdultBone PlatesBone ScrewsFemaleFracture Fixation, InternalHumansMaleMiddle AgedPerioperative CareRadiographyRadius FracturesUltrasonographyWrist InjuriesWrist JointYoung AdultDistal radiusDorsal cortex penetrationScrew penetrationUltrasonic evaluationVolar plating

Identifiers

PMID29615100
PMCPMC5883576
OpenAlexW2806725437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.