Evidence map›Paper›PMID 29611386›Full record

ArticleAnnals of laboratory medicine2018

Comparison of Four Automated Carcinoembryonic Antigen Immunoassays: ADVIA Centaur XP, ARCHITECT I2000sr, Elecsys E170, and Unicel Dxi800.

Joonhong Park, Seungok Lee, Yeongsic Kim, Aeran Choi, Hyeyoung Lee, Jihyang Lim, Yonggoo Kim, Kyungja Han, Eun Jee Oh

Open access · diamondAbstract readComparative Study
In one paragraph

Article in Annals of laboratory medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Joonhong ParkDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Seungok LeeDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Yeongsic KimDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Aeran ChoiDepartment of Laboratory Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
Hyeyoung LeeDepartment of Laboratory Medicine, Samkwang Medical Laboratories, Seoul, Korea.
Jihyang LimDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Yonggoo KimDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Kyungja HanDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Eun Jee OhDepartment of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
Catholic University of Korea · KRSeoul St. Mary's Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCarcinoembryonic antigen (CEA) is one of the tumor markers available for evaluating disease progression status after initial therapy and monitoring subsequent treatment modalities in colorectal, gastrointestinal, lung, and breast carcinoma. We evaluated the correlations and differences between widely used, automated CEA immunoassays at four different medical laboratories.

methodsIn total, 393 serum samples with CEA ranging from 3.0 to 1,000 ng/mL were analyzed on ADVIA Centaur XP (Siemens Diagnostics, Tarrytown, NY, USA), ARCHITECT i2000sr (Abbott Diagnostics, Abbott Park, IL, USA), Elecsys E170 (Roche Diagnostics, Indianapolis, IN, USA), and Unicel DxI800 (Beckman Coulter, Fullerton, CA, USA), and the results were compared. Deming regression, Passing-Bablok regression, and Bland-Altman analyses were performed to evaluate the data correlation and % differences among these assays.

resultsDeming regression analysis of data from Elecsys E170 and UniCel DxI800 showed good correlation (y=3.1615+0.8970x). According to Bland-Altman plot, no statistically significant bias (-1.78 ng/mL [95% confidence interval: -4.02 to 0.46]) was observed between Elecsys E170 and UniCel DxI800. However, the relative differences of CEA concentrations between assays exceeded the acceptable limit of 30%. Regarding the agreement of positivity with cut-off value 5.0 ng/mL, ARCHITECT i2000sr and Elecsys E170 showed the highest agreement (95.2%), whereas ADVIA Centaur XP and ARCHITECT i2000sr showed the lowest agreement (70.7%).

conclusionsAgreements between automated CEA immunoassays are variable, and individual CEA concentrations may differ significantly between assays. Standardization of serum CEA concentrations and further harmonization are needed.

Indexed as

Carcinoembryonic AntigenHumansImmunoassayReagent Kits, DiagnosticReference ValuesRegression AnalysisCarcinoembryonic AntigenReagent Kits, DiagnosticADVIA Centaur XPARCHITECT i2000srBetween-assay comparisonCarcinoembryonic antigenElecsys E170ElectrochemiluminescenceUnicel DxI800

Identifiers

PMID29611386
PMCPMC5895865
OpenAlexW2795614101

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.