Evidence map›Paper›PMID 29611096›Full record

ArticleInternational journal of computer assisted radiology and surgery2018

Experimental validation of robot-assisted cardiovascular catheterization: model-based versus model-free control.

Xiaomei Wang, Kit-Hang Lee, Denny K C Fu, Ziyang Dong, Kui Wang, Ge Fang, Su-Lin Lee, Alex P W Lee, Ka-Wai Kwok

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Bedside Admittance Control of a Dual-Segment Soft Robot for Catheter-Based Interventions.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  2. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  3. Remote vascular interventional surgery robotics: a literature review.Quantitative imaging in medicine and surgery · 2022
    Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Xiaomei WangThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Kit-Hang LeeThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Denny K C FuThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Ziyang DongThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Kui WangThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Ge FangThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong.
Su-Lin LeeThe Department of Computing, Imperial College London, London, UK.
Alex P W LeePrince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong.
Ka-Wai KwokThe Department of Mechanical Engineering, The University of Hong Kong, Pokfulam, Hong Kong. kwokkw@hku.hk.

Funding

Research Grants Council, University Grants Committee 17202317Research Grants Council, University Grants Committee 17227616Research Grants Council, University Grants Committee 27209515
6 · The paper itself

Abstract

purposeIn cardiac electrophysiology, a long and flexible catheter is delivered to a cardiac chamber for the treatment of arrhythmias. Although several robot-assisted platforms have been commercialized, the disorientation in tele-operation is still not well solved. We propose a validation platform for robot-assisted cardiac EP catheterization, integrating a customized MR Safe robot, a standard clinically used EP catheter, and a human-robot interface. Both model-based and model-free control methods are implemented in the platform for quantitative evaluation and comparison.

methodsThe model-based and model-free control methods were validated by subject test (ten participants), in which the subjects have to perform a simulated radiofrequency ablation task using both methods. A virtual endoscopic view of the catheter is also provided to enhance hand-to-eye coordination. Assessment indices for targeting accuracy and efficiency were acquired for the evaluation.

results(1) Accuracy: The average distance measured from catheter tip to the closest lesion target during ablation of model-free method was 19.1% shorter than that of model-based control. (2) Efficiency: The model-free control reduced the total missed targets by 35.8% and the maximum continuously missed targets by 46.2%, both indices corresponded to a low p value ([Formula: see text]).

conclusionThe model-free method performed better in terms of both accuracy and efficiency, indicating the model-free control could adapt to soft interaction with environment, as compared with the model-based control that does not consider contacts.

Indexed as

Cardiac CathetersModels, TheoreticalPrinting, Three-DimensionalAdultArrhythmias, CardiacCardiac CatheterizationCatheter AblationFemaleHumansMaleReproducibility of ResultsRoboticsSurgery, Computer-AssistedYoung AdultCardiac electrophysiologyEndoscopic viewModel-based controlModel-free controlMR SafeRobotic catheterization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.